Modular Support Systems Technical Guide , Edition 1
3.0 MODULAR SUPPORT SYSTEM 3.2.2 MT BASE CONNECTORS MT-B-G WS NC
Description
Weldable starter bracket for all MT girders .
Material Specifications
Standard 1
Grade 1
F y
, ksi ( MPa )
F u
, ksi ( MPa )
GB / T 1591
Q355 B
51.49 ( 355 )
68.17 ( 470 )
1 . Mechanical properties of GB / T 1591 Grade Q355 B meet or exceed the mechanical properties of ASTM A1011 SS Grade 50 .
Corrosion Protection
Zinc ( Ethyl ) Silicate Primer
MT-B-G WS NC 1 ( Weldable Primer )
������ “)
����� ����� “ x ���� “) �
1 . " NC " indicates " non-coated ".
Ordering Information
Description
Weight Per Piece lbs ( kg )
Quantity Piece ( s )
Item No .
MT-B-G WS NC 9.58 ( 4.34 ) 4 2272109
���
������ “)
mm ( in )
���
������ “)
Figure 24 - MT Girder Connection
Table 105 - Allowable Strength Design ( ASD ) Load Data 1 , 2 , 3 , 4
F x lb ( kN )
F y lb ( kN )
F z lb ( kN )
M y lb ft ( kN m )
M z lb ft ( kN m )
10,030
2,620
2,830
1,090
1,090
( 44.62 )
( 11.67 )
( 12.61 )
( 1.48 )
( 1.48 )
1 . Minimum safety factor , Ω , for tabulated values is 2.1 . 2 . Multiply tabulated values by 1.5 to obtain minimum Load and Resistance Factor Design
( LRFD ) values . 3 . Welds to be checked by the design professional . 4 . See Figure 24 .
Table 106 - Limit State Design ( LSD ) Load Data 1 , 2 , 3
A . MT-70 / 80 / 90 / 100
F x lb ( kN )
F y lb ( kN )
F z lb ( kN )
M y lb ft ( kN m )
M z lb ft ( kN m )
12,880
3,940
4,260
1,635
1,635
( 57.31 )
( 17.53 )
( 18.96 )
( 2.22 )
( 2.22 )
1 . Maximum resistance factor , Φ , for tabulated values is 0.70 . 2 . Welds to be checked by the design professional . 3 . See Figure 24 .
2023