Product Technical Guides : US-EN Firestop Systems Guide For Specifiers | Page 689

Estimating Tables TABLE 1 Top of wall joint estimation table for CFS-S SIL GG, CP 606 and CP 506 (Fluted deck only — deck ribs perpendicular to wall), table is based on a 1/2" joint and no excess overspray of sealant. 1/2" 1-1/2" 2" 3" 1.2 lineal feet/10.5 oz. tube 1.1 lineal feet/10.5 oz. tube 0.82 lineal feet/10.5 oz. tube 2.2 lineal feet/600 ml foil pack 2.1 lineal feet/600 ml foil pack 1.5 lineal feet/600 ml foil pack 14.1 lineal feet/gallon 13.5 lineal feet/gallon 10.0 lineal feet/gallon Height of flute Joint Width Estimations based upon 1/2" product depth on both sides of the wall. For 1/4" depth, multiply lineal feet values by 2. Estimates may vary depending on deck type. All estimates are approximate, and assume no waste. Reference the appropriate UL systems for mineral wool requirements. Top of wall joint estimation table for CFS-S SIL GG, CP 606 and CP 506 (Fluted deck only, gypsum cut to fit deck profile — deck ribs perpendicular to wall) Height of flute Joint Width 1/2" 1-1/2" 2" 3" 1.9 lineal feet/10.5 oz. tube 2.1 lineal feet/10.5 oz. tube 1.9 lineal feet/10.5 oz. tube 3.5 lineal feet/600 ml foil pack 4.0 lineal feet/600 ml foil pack 3.6 lineal feet/600 ml foil pack 23.2 lineal feet/gallon 26.1 lineal feet/gallon 23.6 lineal feet/gallon TABLE 2 Estimations based upon 5/8" product depth on both sides of the wall. For 1-1/4" depth, divide lineal feet values by 2. Estimates may vary depending on deck type. All estimates are approximate, and assume no waste. General joint estimation table for CFS-S SIL GG, CFS-S SIL SL, CP 606 and CP 506 (floor to floor, floor to wall, wall to wall, top of wall), table is based on a 1/2" joint and no excess overspray of sealant. Joint Width Lineal Feet/10.5 oz. Tube Lineal Feet/600 ml Foil Pack Lineal Feet/Gallon Sealant Depth (in.) Sealant Depth (in.) Sealant Depth (in.) 1/4 1/2 5/8 1-1/4 1/4 1/2 5/8 1-1/4 1/4 1/2 5/8 1/4" 25.2 12.6 10.08 5.04 48.0 24.0 19.2 9.6 308 154 123 1-1/4 61 1/2" 12.6 6.3 5.04 2.52 24.0 12.0 9.6 4.8 154 77 61 30 8.4 4.2 3.36 1.68 16.0 8.0 6.4 3.2 102 51 41 20 1" 6.3 3.15 2.52 1.26 12.0 6.0 4.8 2.4 76 38 30 15 1-1/4" 5.04 2.52 * * 9.6 4.8 * * 60 30 * * 1-1/2" 4.2 2.1 * * 8.0 4.0 * * 50 25 * * 2" 3.14 1.57 * * 6.0 3.0 * * 38 19 * * 2-1/2" 2.52 1.26 * * 4.8 2.4 * * 30 15 * * 3" 2.1 1.05 * * 4.0 2.0 * * 24 12 * * 3-1/2" 1.8 0.9 * * 3.5 1.7 * * 22 11 * * 6" 1.0 0.52 * * 2.0 1.0 * * 12 6 * * 7" 0.9 0.45 * * 1.7 0.87 * * 11 5.5 * * 8" 0.78 0.39 * * 1.5 0.76 * * 9.6 4.8 * * 3/4" TABLE 3 For wall to wall and top of wall joints, values shown are for one side of the wall only. Divide linear feet values by 2 when covering both sides of wall. Estimates may vary depending on deck type. Reference the appropriate UL systems for mineral wool requirements. Top of wall joint estimation table for CFS-SP WB Firestop Joint Spray and CP 572 (Top of wall with fluted deck), deck ribs perpendicular to wall Height of flute Joint Width 1-1/2" 2" 3" 1/4" 38.5 lineal feet/gallon 34.2 lineal feet/gallon 28.0 lineal feet/gallon 1/2" 34.2 lineal feet/gallon 30.8 lineal feet/gallon 25.6 lineal feet/gallon 3/4" 30.8 lineal feet/gallon 28.0 lineal feet/gallon 23.6 lineal feet/gallon 28.0 lineal feet/gallon 25.6 lineal feet/gallon 22.0 lineal feet/gallon 1-1/2" 23.6 lineal feet/gallon 22.0 lineal feet/gallon 19.2 lineal feet/gallon 2" 20.5 lineal feet/gallon 19.3 lineal feet/gallon 17.1 lineal feet/gallon 2-1/2" 18.1 lineal feet/gallon 17.1 lineal feet/gallon 15.4 lineal feet/gallon 3" 16.2 lineal feet/gallon 15.4 lineal feet/gallon 14.0 lineal feet/gallon 3-1/2" 14.6 lineal feet/gallon 14.0 lineal feet/gallon 12.8 lineal feet/gallon Estimations based upon 1/8" product depth with 1/2" overlap and installation on both sides of the wall. For 1/4" depth, divide lineal feet values by 2. (Note: Quantities may change when used in conjunction with fireproofing material. Refer to specific firestop system for details.) Estimates may vary depending on deck type. All estimates are approximate, and assume no waste. Hilti Firestop Saving lives through innovation and education 687 1" TABLE 4