X-ENP-19 L15 MX and MXR
X-ENP-19 L15
Approvals / Listings
ICC-ES ( International Code Council ) ESR-2776 with LABC / LARC Supplement , ESR-2197 with LABC / LARC Supplement , ESR-1169 , ESR-2657 IAPMO ( Uniform Evaluation Service ) Co-listings ER-0217 , ER-0161 , ER-0329 FM ( Factory Mutual ) For attaching Class 1 Steel Roof Decks with wind uplift ratings up to 1-330 . Refer to FM RoofNav for specific assembly listings . UL ( Underwriters Laboratories ) Fasteners for attaching steel roof deck ( uplift and fire classification ) ABS ( American Bureau of Shipping )
3.5.3 X-ENP-19 FOR FASTENING DECK TO STRUCTURAL STEEL
3.5.3.1 PRODUCT DESCRIPTION
The Hilti structural steel deck fastening system consists of powder-actuated tools which are primarily used with one fastener : the X-ENP-19 L15 , which is available either collated or non-collated .
For most structural steel decking jobs , the tool of choice is the DX 9-ENP tool . This self-contained stand up decking tool is powered by 0.27 caliber long cartridges , which are loaded into the tool in strips of 40 . The cartridges drive the X-ENP-19 L15 MXR fastener ( collated version ) into almost any type of steel deck and base steel thicknesses greater than or equal to 1 / 4 ". These fasteners are available in
3.5.3.2 MATERIAL SPECIFICATIONS
Fastener
Fastener material
Fastener plating
Nominal fastener hardness
X-ENP-19 L15 Carbon Steel 5 µ m Zinc 1 58 HRC
1 ASTM B633 , SC 1 , Type III . Reference Section 2.3.3.1 for more information .
3.5.3.3 TECHNICAL DATA collated strips of 10 . Four of these strips are loaded into the DX 9-ENP tool along with the cartridge strip , and enable the operator to fasten at a rate of up to 1,000 quality fastenings per hour .
Other tools include the hand held DX 76-MX , a semi-automatic magazine tool . Other configurations of the DX 76 include a single fastener guide variation of the tool for miscellaneous use .
Hilti X-ENP-19 steel deck fasteners comply with ANSI / SDI RD1.0 , C1.0 and NC1.0 standards .
Allowable pullout loads for attachments to steel base material lb ( kN ) 1 , 2 , 3
Fastener
Base material thickness ( in .)
1 / 4 3 / 8 1 / 2 4 ≥ 5 / 8 4
X-ENP-19 L15 905 ( 4.03 ) 1125 ( 5.00 ) 1010 ( 4.49 ) 965 ( 4.29 )
1 These values represent testing performed in ASTM A36 plate steel . 2 The values must be compared with allowable tensile pullover values . 3 Allowable values based on safety factor of 5.0 . 4 Allowable values are based on minimum 1 / 2 " penetration depth through or into base steel . For 3 / 8 " penetration depth into
1 / 2 " and thicker steels , reduce the allowable load capacity to 635 lb ( 2.79 kN ).
Allowable pullover and shear bearing loads for attaching steel deck 1 , 2 , 3
Steel deck gauge ( in .)
Fastener
16 ( 0.0598 ) 18 ( 0.0474 ) 20 ( 0.0358 ) 22 ( 0.0295 ) 24 ( 0.0239 ) 26 ( 0.0179 )
Tension lb ( kN )
Shear lb ( kN )
Tension lb ( kN )
Shear lb ( kN )
Tension lb ( kN )
Shear lb ( kN )
Tension lb ( kN )
Shear lb ( kN )
Tension lb ( kN )
Shear lb ( kN )
Tension lb ( kN )
Shear lb ( kN )
X-ENP-19 L15
940 1050 875 840 755 640 665 535 400 440 185 335 ( 4.14 ) ( 4.62 ) ( 3.85 ) ( 3.70 ) ( 3.32 ) ( 2.82 ) ( 2.93 ) ( 2.35 ) ( 1.78 ) ( 1.94 ) ( 0.81 ) ( 1.47 )
1 Minimum base steel thickness must be greater than or equal to 1 / 4 " ( 6 mm ). 2 Allowable values are based on a safety factor of 3.0 . 3 Loads based on ASTM A1008 , or minimum ASTM A653 SQ33 steel deck .