Product Technical Guides : US-EN Direct Fastening - Volume 1 Edition 22 | Page 44

Allowable shear loads for attachment of perimeter track to minimum ASTM A36 ( F y
≥ 36 ksi ; F u
≥ 58 ksi ) steel , lb ( kN ) 1 , 2 , 3 , 4
Shank
Fastener description Fastener diameter in . ( mm )
Universal knurled shank fasteners
Heavy duty fasteners
X-U 0.157 ( 4.0 )
X-U 15 0.145 ( 3.7 )
EDS 0.177 ( 4.5 )
Number of fasteners
3 / 16 lb ( kN )
1 / 4 lb ( kN )
Steel thickness ( in .)
3 / 8 lb ( kN )
1 / 2 lb ( kN )
≥3 / 4 lb ( kN )
1 720 ( 3.2 ) 720 ( 3.2 ) 720 ( 3.2 ) 720 ( 3.2 ) 375 5 ( 1.7 ) 2 1440 ( 6.4 ) 1440 ( 6.4 ) 1440 ( 6.4 ) 1440 ( 6.4 ) 750 5 ( 3.3 ) 1 395 ( 1.8 ) 395 ( 1.8 ) 450 ( 2.0 ) 500 6 ( 2.2 ) 400 6 ( 1.8 ) 2 800 ( 3.6 ) 790 ( 3.5 ) 900 ( 4.0 ) 1000 6 ( 4.5 ) 800 6 ( 3.6 ) 1 615 ( 2.7 ) 870 ( 3.9 ) 870 ( 3.9 ) 960 ( 4.3 ) 655 7 ( 2.9 ) 2 1230 ( 5.5 ) 1740 ( 7.7 ) 1740 ( 7.7 ) 1920 ( 8.5 ) 1310 7 ( 5.8 )
1 The tabulated allowable load values are for the low-velocity fasteners only , using a safety factor that is greater than or equal to 5.0 , calculated in accordance with ICC-ES AC70 . Steel members connected to the substrate must be investigated in accordance with accepted design criteria . 2 Low-velocity fasteners shall be driven to where the point of the fastener penetrates through the steel base material , except as noted . 3 Multiple fasteners are recommended for increased reliability . 4 The minimum edge distance for fastening into steel is 1 / 2 ". Minimum spacing for fastening into steel without reduction in performance is 1 ". 5 Noted tabulated allowable load values are based upon minimum point penetration of 1 / 2 " into the steel . If 1 / 2 " point penetration into the steel is not achieved , but a point penetration of at least 3 / 8 " is obtained , the tabulated shear load should be reduced by 8 percent . 6 Noted tabulated allowable load values are based upon minimum point penetration into the steel of 15 / 32 ". 7 Noted tabulated allowable load values are based upon a minimum point penetration into the steel of 1 / 2 ".
Deflection slip clip applications
Allowable loads for attachment of cold-formed steel deflection slip clips with X-U Universal Powder-Actuated Fasteners 3 , 4 , 5 , 6 , 7 , 8 , 9
Figure Figure 7 : 6 : Normal Normal Weight weight Concrete concrete
Clip
Type 10
Verticlip ®
SLB600 ( 14 GA .)
Fastener
X-U 27
Number of fasteners
Normal weight concrete allowable load 1 lb ( kN )
Lightweight concrete with pour stop allowable load 2 lb ( kN )
2 160 ( 0.7 ) 160 ( 0.7 ) 3 245 ( 1.1 ) 245 ( 1.1 ) 4 330 ( 1.5 ) 380 ( 1.7 )
Figure 8 :
2
125
( 0.6 )
155
( 0.7 )
Lightweight
WSC 950 Concrete with Pour Stop
X-U 27
3
( 16 GA .)
145
( 0.6 )
275
( 1.2 )
4
220
( 1.0 )
275
( 1.2 )
WSC 1500 ( 12 GA .)
FCSC™ ( 14 GA .)
X-U 27
X-U 27
2 90 ( 0.4 ) 130 ( 0.6 ) 3 185 ( 0.8 ) 235 ( 1.1 ) 2 140 ( 0.6 ) 170 ( 0.8 ) 3 290 ( 1.3 ) 320 ( 1.4 )
Location of fasteners
Figure 78 : Lightweight concrete Concrete with pour Pour stop Stop
1 Allowable load based on a safety factor of 5.0 in direction shown in Figure 6 for attachment of deflection slip clip to 4000 psi Normal Weight Concrete Slab .
2 Allowable load based on a safety factor of 5.0 in direction shown in Figure 7 for attachment of deflection slip clip to 3000 psi Lightweight Concrete Slab with 12 GA . sheet steel pour stop with minimum yield strength Fy = 33 ksi . 3 Testing based on deflection slip clips obtained in February 2007 . Subsequent changes by the manufacturer to the deflection slip clip design may affect load values . 4 Allowable load values are for fasteners installed in concrete having the designated compressive strength at the time of installation . 5 Allowable load values are based off of the fixtures tested . Other members connected to the deflection slip clips must be investigated in accordance with accepted design criteria . 6 Spacing of fasteners depends on the design of each deflection slip clip . Fasteners should be installed through the pre-assigned locations in the deflection slip clip . 7 For base material thickness requirements , reference Section 3.2.1.4 . 8 Allowable values are for loads applied perpendicular to the edge of the concrete . 9 Multiple fasteners are recommended for any attachment . 10 Verticlip is a registered trademark of The Steel Network , Inc . Fast Clip Slide Clip ( FCSC ) is a trademark of Ware
Industries Inc .
44