Direct Fastening Technical Guide , Edition 24
Ultimate and allowable shear loads for attachment of perimeter track to 3000 psi light weight concrete 1 , 2 , 3 , 4 , 5 , 6
Fastener description |
Shank diameter in . ( mm ) |
Fastener length in . ( mm ) |
Track width in . 7 |
Number of fasteners |
Ultimate shear load lb ( kN ) |
Allowable shear load lb ( kN ) |
|
|
|
3-5 / 8 1 1290 ( 5.7 ) 260 ( 1.2 ) |
X-U 8 Universal Knurled Shank Fasteners and
X-P 8 Premium Concrete Fastener
|
0.157 ( 4.0 ) |
1 ( 27 )
1-1 / 4 ( 32 )
1-1 / 2 ( 37 )
|
1 |
1290 |
( 5.7 ) |
260 |
( 1.2 ) |
6 |
|
2 |
2585 |
( 11.5 ) |
520 |
( 2.3 ) |
3-5 / 8 |
1 |
2173 |
( 9.7 ) |
350 |
( 1.6 ) |
|
1 |
2173 |
( 9.7 ) |
350 |
( 1.6 ) |
6 |
|
|
|
|
|
|
2 |
2885 |
( 12.8 ) |
575 |
( 2.6 ) |
3-5 / 8 |
1 |
2524 |
( 11.2 ) |
295 |
( 1.3 ) |
|
1 |
2524 |
( 11.2 ) |
295 |
( 1.3 ) |
6 |
|
|
|
|
|
|
2 |
3020 |
( 13.4 ) |
605 |
( 2.7 ) |
|
|
|
|
3-5 / 8 1 1020 ( 4.5 ) 205 ( 0.9 ) |
1 ( 27 ) 6
1 1020 ( 4.5 ) 205 ( 0.9 ) 2 2995 ( 13.3 ) 600 ( 2.7 )
DS 9 Heavy Duty Fasteners |
0.177 ( 4.5 ) |
1-1 / 4 ( 32 ) |
3-5 / 8 |
1 |
1120 |
( 5.0 ) |
225 |
( 1.0 ) |
|
1 |
1120 |
( 5.0 ) |
225 |
( 1.0 ) |
6 |
|
|
|
|
|
|
2 |
2965 |
( 13.2 ) |
595 |
( 2.6 ) |
|
|
|
|
3-5 / 8 1 1075 ( 4.8 ) 215 ( 1.0 ) |
1-1 / 2 ( 37 ) 6
1 1075 ( 4.8 ) 215 ( 1.0 ) 2 2955 ( 13.1 ) 590 ( 2.6 )
1 The tabulated ultimate loads were developed from testing the low-velocity fasteners with 16 gauge ( Fy ≥ 33 ksi ) steel track . A safety factor greater than or equal to 5.0 was used to determine allowable loads . Steel track members not meeting the specification noted must be investigated in accordance with accepted design criteria 2 Allowable values are for fasteners installed in concrete having the designated compressive strength at the time of installation . 3 Spacing and edge distance constraints are as noted in Figures 1-3 on page 42 . 4 Allowable shear load values are for loads applied perpendicular to the edge of the concrete . 5 Multiple fasteners are recommended for any attachment . 6 Minimum edge distance of 3 ” cannot be decreased . Closer edge distances can result in edge breakout failure of the base material during installation . As a result , fasteners are offset from the center line of the track . 7 SSMA track designation for 3-5 / 8 ” track is 362T 150-54 and for 6 ” track is 600T 150-54 . 8 For additional technical data and material specifications for X-U and X-P fasteners , see Section 3.2.6.2 and 3.2.6.3 of this Technical Guide . 9 For additional technical data and material specifications for DS fasteners , see section 3.2.5 of this Technical Guide .