Product Technical Guides : US-EN Direct Fastening - Volume 1 Edition 22 | Page 153

Direct Fastening Technical Guide , Edition 24
2 . Full scale diaphragm system tests ( cantilever tests )
Figure 2 : Small element connection tests
Full scale diaphragm system tests are used to determine the strength and stiffness of a larger steel deck diaphragm assembly directly . The data is analyzed and fit in a predictive model to address varying configurations of base steel , steel deck , specific fastener combinations and spans . These tests are conducted in accordance with the following standards and shown in Figures 3 , 4 and 5 .
• ICC-ES AC43 Acceptance Criteria for Steel Deck Roof and Floor Systems
• AISI S907 Cantilever Test Method for Cold-Formed Steel Diaphragms
• ASTM E455 Standard Test Method for Static Load Testing of Framed Floor or Roof Diaphragm Constructions for Buildings
Figure 3 : ICC-ES AC43 diaphragm test frame schematics
30 ' -0 "
24 ' -0 "
Figure 4 : AC43 diaphragm test frame Fastening Systems Research Laboratory ( FSRL ), Schaan , Liechtenstein
153