Product Technical Guides : US-EN Direct Fastening - Volume 1 Edition 22 | Page 143

Direct Fastening Technical Guide , Edition 24
Product selection guide for checkerplate
Fastening height in . ( mm ) X-FCP Disk 1 DX 460-GR Stud
1 / 4 to 21 / 64
X-FCP-F5 / 10
X-ST-GR M8 / 5 P8
( 6.4 to 8.3 )
X-FCP-R5 / 10
Stud Stand-off 31 / 64 " – 37 / 64 "
11 / 32 to 1 / 2
X-FCP-F5 / 10
X-ST-GR M8 / 10 P8
( 8.7 to 12.7 )
X-FCP-R5 / 10
Stud Stand-off 41 / 64 " – 25 / 32 "
1 / 4 to 1 / 2 ( 6.4 to 12.7 )
X-FCP sealing ring Optional
1 X-FCP-F = Duplex Coated Carbon Steel , X-FCP-R = Stainless
Installation procedure for checkerplate 1
1 . Place and align the plate section following recognized safety precautions .
T rec 3.7 – 6 ft‐lb ( 5-8 Nm )
2 . Install the 8 mm stainless threaded stud through the pre-drilled hole .
3 . Start the X-FCP on the stud by hand .
4 . Tighten the disk , without exceeding maximum tightening torque .
h NVS
= Stud Stand‐off Length
1 Installation Instructions For Use ( IFU ) are included with each product package . They can also be viewed or downloaded online at www . hilti . com . Because of the possibility of changes , always verify that downloaded IFU are current when used . Proper installation is critical to achieve full performance . Training is available on request . Contact Hilti Technical Services for applications and conditions not addressed in the IFU .
143