3.3.2.3 TECHNICAL DATA
Allowable loads in normal weight concrete 1 , 2 , 3
Fastener designation
Concrete compressive strength
4,000 psi 6,000 psi
Load direction
Tension lb ( kN )
45-degree lb ( kN )
Tension lb ( kN )
45-degree lb ( kN )
X-CX ALH22 90 ( 0.40 ) 125 ( 0.56 ) 90 ( 0.40 ) 125 ( 0.56 ) X-CX ALH27 125 ( 0.56 ) 165 ( 0.73 ) 110 ( 0.49 ) 150 ( 0.67 ) X-CX ALH32 160 ( 0.71 ) 210 ( 0.93 ) 145 ( 0.64 ) 200 ( 0.89 ) X-CX C27 90 ( 0.40 ) 125 ( 0.56 ) - -
1 The tabulated allowable load values are for the powder-actuated ceiling clip assemblies only , using a safety factor that is greater or equal to 5.0 , calculated based on testing in accordance with ICC-ES AC70 and ASTM E1190 . Connected components , including wires , must be investigated separately . 2 Multiple fasteners are recommended for any attachment . 3 The concrete thickness at the point of penetration must be a minimum of three times the fastener embedment depth .
Allowable Loads in structural 3000 psi lightweight concrete over metal deck 1 , 2 , 3 , 4
Fastener designation
Lower flute
Fastener location
Upper flute
Load direction
Tension lb ( kN )
45-degree lb ( kN )
Tension lb ( kN )
45-degree lb ( kN )
X-CX ALH22 90 ( 0.40 ) 110 ( 0.49 ) 110 ( 0.49 ) 110 ( 0.49 ) X-CX ALH27 120 ( 0.53 ) 125 ( 0.56 ) 150 ( 0.67 ) 130 ( 0.67 ) X-CX ALH32 150 ( 0.67 ) 145 ( 0.64 ) 190 ( 0.85 ) 160 ( 0.71 ) X-CX C27 80 ( 0.36 ) 110 ( 0.49 ) 110 ( 0.49 ) 110 ( 0.49 )
1 . The tabulated allowable load values are for the powder-actuated ceiling clip assemblies only , using a safety factor that is greater or equal to 5.0 , calculated based on testing in accordance with ICC-ES AC70 and ASTM E1190 . Connected components , including wires , must be investigated separately . 2 . Multiple fasteners are recommended for any attachment . 3 . The concrete thickness at the point of penetration must be a minimum of three times the fastener embedment depth . 4 . Deck panel must be a 3-inch deep composite floor deck and have a minimum 0.0358 inch base-metal thickness , a minimum yield strength of 40 ksi and a minimum tensile strength of 55 ksi .
Allowable loads in minimum ASTM A36 ( Fy ≥ 36 ksi ; Fu ≥ 58 ksi ) steel 1 , 2 , 3
Fastener designation
Steel thickness in .
1 / 4 3 / 8 1 / 2 4
Load direction
Tension lb ( kN )
45-degree lb ( kN )
Tension lb ( kN )
45-degree lb ( kN )
Tension lb ( kN )
45-degree lb ( kN )
X-CX ALH22 260 260 260 260 260 260
1 The tabulated allowable load values are for the powder-actuated ceiling clip assemblies only , using a safety factor that is greater or equal to 5.0 , calculated based on testing in accordance with ICC-ES AC70 and ASTM E1190 . Connected components , including wires , must be investigated separately . 2 Low-velocity fasteners shall be driven to where the point of the fastener penetrates through the steel base material , except otherwise noted . 3 Multiple fasteners are recommended for any attachment . 4 For fastening into 1 / 2-inch or thicker steel , DX460 / DX5 with black cartridge may be needed . For more information , contact Hilti technical service .
137