Product Technical Guides : US-EN Direct Fastening - Volume 1 Edition 22 | Page 113

Direct Fastening Technical Guide , Edition 22
3.2.17.5 ORDERING INFORMATION
X-DH and X-DH BW Data Hook *
Fastener description
Batwing attachable to
Number of CAT 5e cables
( 70 % fill rate )
Number of CAT 6 cables ( 70 % fill rate )
Number of CAT 6A cables ( 70 % fill rate )
With preassembled batwing , max . recommended overbending distance 1 in . ( 25 mm ) X-DH 1 " BW
X-DH 2 " BW
X-DH 4 " BW
1 / 4-inch rod , 8-12 ga wire
1 / 4-inch rod , 8-12 ga wire
1 / 4-inch rod , 8-12 ga wire
Without preassembled batwing
30 20 12 10
95 70 40 35
360 260 155 125
X-DH 2 " C N / A 95 70 40 35 X-DH 2 " N / A 95 70 40 35 X-DH 4 " N / A 360 260 155 125
Number of CAT 7A cables ( 70 % fill rate )
X-MS MC Stacker *
Fastener description
Batwing attachable to
Max . pieces of 14-2 MC cables
Max . pieces of 8-3 MC cables With preassembled batwing , max . recommended overbending distance 1 in . ( 25 mm ) X-MS 3 " BW
1 / 4-inch rod , 8-12 ga wire
Without preassembled batwing
7 4
X-MS 3 " N / A 7 4
X-BR Bridle Ring *
Fastener description
With premounted fastener
Fastener length in . ( mm )
Fastener shank Ø in . ( mm ))
Number of fire alarm 18 / 2 cables ( 70 % fill rate )
X-BR 1-1 / 4 " ALH 27 1 ( 27 ) 0.177 ( 4.5 ) 39 1 X-BR 2 " ALH27 1 ( 27 ) 0.177 ( 4.5 ) 60 3 Without premounted fastener X-BR 1-1 / 4 " MX N / A N / A 39 1 X-BR 2 " MX N / A N / A 60 3
* For spacing requirements , please refer to TIA 569 .
Number of MC Cables
113