Product Technical Guides : US-EN Cast-In Anchor Channel Fastening Technical Guide | Page 66

1. Anchor Channel Systems 2. HAC Portfolio 3. HAC Applications 4. Design Introduction 5. Base material 6. Loading 8. Reinforcing Bar Anchorage 9. Special Anchor Channel Design 10. Design Software 11. Best Practices 12. Instructions for Use 13. Field Fixes 14. Design Example Hilti Locking Channel Bolt Length Mechanical interlock between channel lip and locking channel bolts via channel lip notches 7. Anchor Channel Design Code Table 2.2.11.3 — Hilti Locking Channel Bolts dimensions Channel Bolt units b 2 mm 33 (1.30) 40-300 (1.57-7.87) 13.9 M20 (in) (1.57-7.87) 60-300 (0.55) (2.36-7.87) Anchor Channel profile Channel lip thickness, L th 7/64 in HAC-40 (2.6 mm) 1/8 in HAC-50 HAC-50 S (3.10 mm) 5/32 in HAC-60 (4.1 mm) N h occurs after the installation torque is applied to the HBC-C-N t-bolt and the 2 mm deep notches are created in the lips of the anchor channel. (5.2 mm) Figure 2.2.11.5 — Overhang of Hilti Locking Channel Bolt (HBC-C-N). 12 2 mm 16 2 mm 20 2 mm Property class - 8.8 ksi 116.0 f u f y Coating (N/mm 2 ) (800) ksi 92.82 (N/mm ) 2 Table 8-2 — I nstallation torque for Hilti Locking Channel Bolts (HBC-C-N) Installation torque T inst (Installation type A) 1 Bolt type Units HAC-40 HBC-C-N M12 8.8 HBC-C M16 8.8 HBC-C-N M20 8.8 Installation torque T inst (Installation type B) 2 ft-lb (Nm) ft-lb (Nm) ft-lb (Nm) HAC-50 HAC-50 S HAC-60 HAC-70 HAC-40 HAC-50 HAC-50 S HAC-60 HAC-70 55 (75) 136 (185) 236 (320) 1 Installation type A: The fixture is in contact with the channel profile and the concrete surface 2 Installation type B: The fixture is fastened to the anchor channel by suitable steel part (e.g. square plate washer), fixture is in contact with the channel profile only 66 Cast-In Anchor Channel Product Guide, Edition 1 • 02/2019 67 1 Materials according to Annex 3, Table 1 2 Hot-dop galvanized Although there is minimum t-bolt overhang (Lo) can be zero, for tolerance purposes it is recommended to have a minimum t-bolt overhang. Table 2.2.11.5 provides the minimum t-bolt overhang length. Installation Torque (640) F 2 (7 mm) Carbon steel 1 M20 Units (5 mm) 9/32 in Channel bolt 13/64 in M16 Table 2.2.11.2 — Hilti Locking Channel Bolts (HBC-C-N) material information (3 mm) Hilti Locking Channel bolt grade Notch in channel lip created by HBC-C-N after installation torque; 4 total. If needed, the excess at the end of the bolt can be cut-off. The nut shall be fully engaged. The outside face of the head of the t-bolt has special markings to identify the t-bolt type and proper head orientation of the t-bolt. If the t-bolt is to be cut or grind, inspect and ensure the orientation and t-bolt type is as specified. 1/8 in M12 There is no maximum thread protrusion limitation from the standpoint of the function of the bolt. The extra 2 mm shall be considered when determining the protruding length ( l ef ) of the Hilti Locking Channel Bolt Minimum nominal overhang, L o N h Hilti locking channel bolt diameter (mm) Diameter (mm) Table 2.2.11.5 — Recommended t-bolt overhang, L o According to AISC Steel Construction Manual, 13th Edition, Section 14-10: “Adequate thread engagement for anchor rods is identical to the condition described in the RCSC Specification as adequate for steel to steel structural joints using high strength bolts: having the end of the [anchor rod] flush with or outside the face of the nut”. Channel Bolt Minimum bolt overhang Table 2.2.11.1 — Depth of notches created by Hilti Locking Channel Bolts (HBC-C-N) 13/64 in HAC-70 Figure 2.2.11.4 – Notches in channel lips due to HBC-C-N. Table 2.2.11.4 — Channel lip thickness mm 11.4 (0.45) 18.5 (0.73) M16 (in) L 40 M12 (in) k mm HAC-40 HAC-50 HAC-50 S HAC-60 HAC-70 b 1 Diameter ø HBC-C-N Channel bolt length Dimensions Anchor Channel Profile