Product Technical Guides : US-EN Cast-In Anchor Channel Fastening Technical Guide | Page 380

1. Anchor Channel Systems 2. HAC Portfolio 3. HAC Applications 4. Design Introduction 5. Base material 6. Loading 14. DESIGN EXAMPLES 7. Anchor Channel Design Code 8. Reinforcing Bar Anchorage 9. Special Anchor Channel Design 10. Design Software 11. Best Practices 12. Instructions for Use 13. Field Fixes 14. Design Example 14.1 DESIGN EXAMPLES This chapter provides a step by step detail explanation of every single failure mode of an anchor channel with rounded head anchors. Figure 14.1.3 — Design example – Bracket Plan View Figure 14.1.1 — Design example - Facade Connection Given: Floor - Floor height = 10.5’ Mullion Spacing = 5’ DL = 14 psf Wind Pressure (ASD) = 40psf Code = ASCE 7-10 Snap shot from structural notes Figure 14.1.4 — Design example – Bracket Section View Seismic provision will not apply since the project is located in SDC B. Concrete ---- f ΄c = 6000psi c a1 =5.00” λ=1.0 (normal weight concrete) HAC-50 106/350 F is used with (2) HBC-C 8.8F, M16x60 h ef = 4.173 in. Figure 14.1.2 — Design example – Structural notes Length: 13.8 in., anchor spacing: 5.906 in., projection: 0.984 in., width: b ch = 1.650 in., height: h ch = 1.220 in. Please refer to chapter 02 for properties of the channel. 380 Cast-In Anchor Channel Product Guide, Edition 1 • 02/2019 381