Product Technical Guides : US-EN Cast-In Anchor Channel Fastening Technical Guide | Page 296

1. Anchor Channel Systems 2. HAC Portfolio 3. HAC Applications 4. Design Introduction 5. Base material Anchor reinforcement steel: ΦN ca,s ΦN pn > N aua ΦN ca,s > N aua The concrete pull out capacity is in accordance to ESR-3520 Sec. 4.1.3.2.4. Please refer to table 2.2.7.1, 2.2.7.2, 2.2.7.3, 2.2.16.1, 2.2.16.2 and 2.2.16.3 of chapter 02 for parameters and section 7.3.2 of anchor channel theory chapter 07 for analysis. The anchor reinforcement steel capacity is in accordance to ESR- 3520 Sec. 4.1.3.2.3. Please refer section 7.2.2 of anchor channel theory chapter 07 for analysis. Rebar connection Anchor reinforcement steel: ΦN ca,s ΦN ca > N aua 12. Instructions for Use Blow-out: ΦN sb Concrete Failure Modes Rebar in tension Concrete Failure Modes Anchor reinf. steel EDGE Rebar pull-out SLS Concrete edge ESR-3520 Sec. 4.1.3.3.2, 4.1.3.4.2 Anchor ESR-3520 Sec. 4.1.3.3.2, 4.1.3.4.2 Hilti Method (Rebar pull- out and Rebar connection are performed in the same way as for the FoS products.) N/A Not permitted Hilti Method based on ACI Remark in Profis Not permitted Concrete Breakout Hilti Method Concrete Pryout ESR-3520 Sec. 4.1.3.3.4 The value of V sl,y is valid only if the center-to-center distance between the channel bolt under consideration and adjacent channel bolts, s bch is at least s chb,cr,V . If this requirement is not met then the value of V sl,y must be reduced as follow: Channel lip : фV sl,y фV sl,y > V bua The capacity of channel lip is in accordance to ESR-3520 Sec. 4.1.3.2.2. Please refer to table 2.3.22 and 2.3.6 of chapter 02. Anchor channel casted into concrete in combination with the EDGE Plate with two bolts in different positions and with different spacing were tested under shear load. A failure for local bending of the channel lip was observed and the failure load was depending on the bolt spacing. According to AC232, for the chosen spacing of 75 mm and 100 mm, there should be no mutual influence of the two bolts on the lip failure load. The lower observed failure loads are probably caused by the disturbance into concrete introduced by the plate or from the crack which appears with a small edge distance. In order to cover this failure a reduction factor for the channel lip strength is proposed as ψ s, sl . The reduction factor is similar to that for the nominal strength of the channel lip to take up tension loads of ESR 3520 [1] (eq. 5 in 4.1.3.2.2). V sl , y = y s , sl . V sl , y , technical data y s,sl = Channel lip : фV sl,y 1 1.5 é æ ö V b , j ù s ú 1 + å i n = + 2 1 ê ç ç 1 - chb,i ÷ ÷ × ua b ê è s chb,cr,V ø V ua , a 1 ú ë û s chb , cr , V = s chb , cr ,0 - 0.9 c a 1 ³ 3 d s c  ritical bolt spacing for shear load for the HAC-50. where Where V ua b , j ; V ua b ,1 ® + same dir . i  n case one bolt is loaded in the opposite direction no positive effect on the factor is considered The bolt shear forces are considered only if acting in the same direction. If one bolt is loaded in the opposite direction no positive effect on the factor is considered. Cast-In Anchor Channel Product Guide, Edition 1 • 02/2019 297 **If the clip is selected V sl,y , V sl,y , V sc,y are changed in clip direction, and only static No (The rebar welding is specified such as to have an higher strength than the rebar itself ) Anchor reinf. anchorage Connection 14. Design Example Steel Failure Modes 13. Field Fixes The anchor reinforcement anchorage capacity is in accordance to ESR- 3520 Sec. 4.1.3.2.3. Please refer section 7.2.2 of anchor channel theory chapter 07 for analysis. PERPENDICULAR SHEAR 296 11. Best Practices Steel Failure Modes Anchor reinforcement anchorage: ΦN ca Hilti Method** 10. Design Software The concrete side-face blow-out capacity is in accordance to ESR- 3520 Sec. 4.1.3.2.5. Please refer to table 2.2.7.1, 2.2.7.2, 2.2.7.3, 2.2.16.1, 2.2.16.2 and 2.2.16.3 and table 2.2.14.1 of chapter 02 for parameters and section 7.2.2 of anchor channel theory chapter 07 for analysis. ESR-3520 Sec. 4.1.3.3.2, 4.1.3.4.2 9. Special Anchor Channel Design Rebar Failure Modes Anchor reinforcement anchorage: ΦN ca ΦN sb > N aua Channel Lip 8. Reinforcing Bar Anchorage N/A Pullout: ΦN pn Side-face blow-out: ΦN sb Channel bolt: 7. Anchor Channel Design Code Pull out: ΦN pn 6. Loading