Product Technical Guides : US-EN Cast-In Anchor Channel Fastening Technical Guide | Page 172

1. Anchor Channel Systems 2. HAC Portfolio 3. HAC Applications 4. Design Introduction 5. Base material 6. Loading ϕ factor for concrete breakout strength in tension Condition A (ϕ=0.75) is considered when Cracked • No Supplementary reinforcement is present Uncracked 10. Design Software 11. Best Practices 12. Instructions for Use 13. Field Fixes 14. Design Example Anchor reinforcement in tension As opposed to supplementary reinforcement, anchor reinforcement acts to transfer the full design load from the anchors into the reinforcement. Hence, concrete breakout is precluded. Where anchor reinforcement is developed in accordance with ACI 318 on both sides of the breakout surface for an anchor of an anchor channel, the design strength of the anchor reinforcement shall be permitted to be used instead of the concrete breakout strength in determining ΦNn or ΦVn, dependent upon the if the load is tension or shear. A strength reduction factor of 0.75 shall be used in the design of the anchor reinforcement. Anchor reinforcement can be utilized in tension, longitudinal shear, and perpendicular shear. An explicit design and full development are required for anchor reinforcement. Condition B (ϕ =0.70) is considered when 9. Special Anchor Channel Design ψ cp,N = modification factor for splitting ϕ A B 0.75 0.70 In accordance with the provisions of AC232 D5.2.10.9, the tension anchor reinforcement shall consist of stirrups made from deformed reinforcing bars with a maximum diameter of 5/8 in (No. 5 bar) c ac = critical edge distance for splitting c cr,N = critical anchor edge distance c s,min = minimum edge distance ψ cp,N ed Concrete Uncracked With Supplementary Reinforcement concrete with Cracked Concrete reinforcement supplementary y cp , N Figure 7.3.2.17 — Arrangement of anchor reinforcement for anchor channels loaded in tension, plan view. 1 ì æ c a , min = MAX í ç ç î è c ac ö ÷ ÷ ø æ c cr , N ; ç ç è c ac ö ü ÷ ÷ ý ø þ 1 1 1 1 = effective embedment depth = factored tension load = development length = development length in tension of a deformed bar or deformed wire with a standard hook, measured from critical section to outside end of hook Figure 7.3.2.17 — Arrangement of anchor reinforcement for anchor channels loaded in tension, section view. Where anchor reinforcement is developed in accordance with ACI 318-11 Chapter 12 or ACI 318-14 Chapter 25 on both sides of the breakout surface for an anchor of an anchor channel, the design strength of the anchor reinforcement, ϕN ca , shall be permitted to be used instead of the concrete breakout strength, ϕN cb , in determining ϕN n . The anchor reinforcement for one anchor shall be designed for the tension force, N aua , on this anchor using a strut-and-tie model. The provisions in Figure - 7.3.2.17 shall be taken into account when sizing and detailing the anchor reinforcement. Anchor reinforcement shall consist of stirrups made from deformed reinforcing bars with a maximum diameter of 5/8 in. (No. 5 bar) (16 mm). A strength reduction factor, ϕ, of 0.75 shall be used in the design of the anchor reinforcement. Cast-In Anchor Channel Product Guide, Edition 1 • 02/2019 173 Figure 7.3.2.16 — Arrangement of anchor reinforcement for anchor channels loaded by tension load at an edge. h ef N ua ℓ d ℓ dh The basic concrete breakout strength can be achieved if the minimum edge distance ca,min equals c cr,n . Test results, however, indicate that it require minimum edge distances exceeding c cr,n to achieve the basic concrete breakout strength when tested in uncracked concrete without supplementary reinforcement to control splitting. When a tension load is applied, the resulting tensile stresses at the embedded end of the anchor are added to the tensile stresses induced due to anchor installation, and splitting failure may occur before reaching the concrete breakout strength. To account for this potential splitting mode of failure, the basic concrete breakout strength is reduced by a factor ψ cp,N if c a,min is less than the critical edge distance c ac . If supplementary reinforcement to control splitting is present or if the anchors are located in a region where analysis indicates cracking of the concrete at service loads, then the reduction factor ψ cp,N is taken as 1.0. The 172 Figure 7.3.2.15 — Arrangement of anchor reinforcement for anchor channels loaded by tension load in a narrow member. Cracked concrete 1 If c a,min ESR < c ac 3520 ESR 3520 eq (18) If CaminCac a,min ESR 3520 eqn (17) The modification factor for anchor channels designed for uncracked concrete without supplementary reinforcement to control splitting, ψ cp,N , shall be computed in accordance with Eq. (17) or (18). The critical edge distance, c ac , shall be taken from Table 8-4 of ESR-3520. Condition Tension* (AC232 D5.2.10.9) Figure 7.3.2.14 — Cracked and uncracked concrete. • Supplementary reinforcement is present • Reinforcement does not need to be explicitly designed for the anchor channel • Arrangement should generally conform to anchor reinforcement • Development is not required 8. Reinforcing Bar Anchorage presence of supplementary reinforcement to control splitting does not affect the selection of Condition A or B. Cracks 7. Anchor Channel Design Code