Product Technical Guides : US-EN Cast-In Anchor Channel Fastening Technical Guide | Page 166

1. Anchor Channel Systems 2. HAC Portfolio 3. HAC Applications 5. Base material 6. Loading maximum width of the slot between the channel lips. Insert the channel bolt in the channel profile and apply the load with a coupling nut to avoid thread failure. Alternatively, in case of standard channel bolts, channel bolts may be tested in a steel template (Figure 7.3.1.6 b). This template shall represent the inner profile of the channels. 7. Anchor Channel Design Code 8. Reinforcing Bar Anchorage 9. Special Anchor Channel Design 10. Design Software In tension Test No. 4 the distance between the support reaction and any loaded anchor may be smaller than 2h ef to avoid concrete failure. 1 Where the center-to-center spacing between channel bolts shall not be less than 3-times the bolt diameter d s . 13. Field Fixes 14. Design Example The value calculated from Eq. (17.4.3.4) corresponds to the load at which crushing of the concrete occurs due to bearing of the anchor head (CEB 1997; ACI 349). It is not the load required to pull the anchor completely out of the concrete, so the equation contains no term relating to embedment depth. Local crushing of the concrete greatly reduces the stiffness of the connection, and generally will be the beginning of a pullout failure. In lightweight concrete subjected to tensile stress, the aggregate fractures and the surface of the crack is, compared to the fracture process in concrete containing normal weight aggregate, relatively smooth. Therefore, the descending (strain softening) part of the load-deformation curve for normal weight concrete is less steep than in the case of lightweight concrete. Hence the strength is reduced using reduction factor λ. Figure 7.3.1.6 — Test on channel bolts, test series No. 3. Channel Flexural Strength, фM s,flex where A use,N is the effective cross-sectional area in tension, in 2 (mm 2 ); and f utb shall be taken as the smaller of 1.9f yb and 125,000 psi (860 MPa) 166 In Test No. 4, concrete failure shall be avoided. This may be achieved by testing anchor channels with anchors that have an increased embedment depth. Per ESR-3520 Section 4.1.3.2.4, nominal pullout strength (N pn ) is calculated using ACI 318 anchoring to concrete provisions. ACI 318-11 Appendix D and ACI 318-14 Chapter 17 provisions. ϕN pn ≥ N aua N pn = Ψ c,P . λ . N p reference ACI 318-14 Eq. (17.4.3.1) N p = 8 A brg f’ c reference ACI 318-14 Eq. (17.4.3.4) f’ c = concrete compressive strength A brg for anchor channel is found in ESR-3520 Table 8-1 λ = modification factor for lightweight concrete λ = 1 for Normal weight concrete λ = 0.85 for Sand Light weight concrete λ = 0.75 for All Light weight concrete Figure 7.3.2.2 — Concrete cone in cracked (left) and uncracked (right) concrete. A cracked tension zone is assumed because concrete possesses relatively low tensile strength, which may be fully or partly used by internal or restraint tensile stresses not taken into account in the design. The load-bearing behavior of an anchor can be significantly influenced by the presence of a crack passing through the anchor location. For anchor channels located in a region of a concrete member where analysis indicates no cracking at service load levels, the following modification factor shall be permitted ψ c,p = 1.25 Where analysis indicates cracking at service load levels ψ c,p shall be taken as 1.0. Concrete ψ c,p Cracked Uncracked 1.00 1.25 Cast-In Anchor Channel Product Guide, Edition 1 • 02/2019 167 Test No. 3 is performed to evaluate the strength of the head of the channel bolt. All channel bolt sizes have been tested. For test No. 3, test the channel bolts in a section of channel that is sufficiently restrained to cause failure of the channel bolt (Figure 7.3.1.6 a). If the channel bolt is intended to be used for different channel sizes, conduct the tests in the channel profile with the Pull-out and pull-through failure is characterized by the anchor being pulled out, whereby the concrete in the immediate vicinity of the anchor may not be damaged.  he nominal strength of the channel T bolt, N ss , shall not exceed the value determined in accordance with the following equation: N ss ≥ A use,N .f utb The flexural strength of an anchor channel shall be established in accordance to Test No. 4 of AC232. The purpose of this test is to measure the bending strength of the channel taking account of the restraint of the deformation of the outer ends of the channel by the concrete. The tests shall be performed with all sizes and materials of anchor channels. Anchor channels with two anchors with a maximum spacing and the minimum distance between the end of the channel and the anchor axis as specified by the manufacturer and with an anchor type that provides the lowest anchor strength shall be tested. The channel bolt with the smallest head size and maximum steel strength that, when tested, still results in steel failure of a part of the anchor channel other than the channel bolt shall be used. If the largest channel bolt size still results in bolt failure, the bolt failure load shall be taken as the load corresponding to bending failure. In case of locking channel bolts in combination with non-serrated channels, test has been performed with all channel bolt sizes. Pull Out Strength фN pn ϕN ss ≥ N bua ϕM s,flex ≥ M u,flex Uncracked Channel bolt strength N ss , and ϕ are tabulated in ESR-3520 Table 8-11 for HAC and HAC-T with Hilti channel bolts (HBC-B, HBC-C, HBC-T and HBC-C-N). Cracked Channel Bolt Strength фN ss 7.3.2 CONCRETE TENSILE STRENGTHS Figure 7.3.2.1 — Influence of crack path on the stress-deformation behavior of concrete. concrete.(Picture from Anchorage in Concrete Construction, R. Eligehausen). Figure 7.3.1.5 — Anchor channel dimensions. Bending strength M s,flex , M s,flex,seis and ϕ are tabulated in ESR-3520 Table 8-3 for HAC and HAC-T with Hilti channel bolts (HBC-C, HBC-T and HBC-C-N). (Figures a and b taken from AC232, Figure 5.8). b) This behavior of anchor channel in concrete is influenced by a multitude of parameters, including the condition of the base material (cracked or uncracked), the direction of the action (tension, shear, combined tension and shear, or shear with lever arm), concrete strength, embedment depth, distance to neighboring fasteners and to edges, nature of the action (transitory, sustained, seismic or shock load) and amount and configuration of proximate reinforcement. In addition, environmental factors such as corrosion, extreme temperatures, and fire can affect anchor performance and must be properly considered in anchor channel design. Figure 7.3.1.7 — Flexural test on anchor channels. Photo of an anchor channel after test; failure by bending of channel and distortion of anchor flanges a) 12. Instructions for Use é æ ù s chb, i ö ÷ N b ua, i ú ç ê × 1 + å 1 - ç ÷ N b ua,1 ú i = 2 ê ch ø 2b è ë û n + 1 2 11. Best Practices The nominal strength of the channel lips to take up tension loads transmitted by a channel bolt, N sl , must be taken from ESR 3520 Table 8-3. This value is valid only if the center-to- center distance between the channel bolt under consideration and adjacent channel bolts, S chb , is at least 2b ch (see fig 7.3.1.5). If this requirement is not met then the value N sl given in table 8-3 must be reduced by the factor 4. Design Introduction