HIT-HY 200 V3 with HIS-N Inserts
Figure 12 — Hilti HIS-N and HIS-RN internally threaded insert installation conditions
Permissible concrete conditions
Uncracked concrete
Cracked concrete
Dry concrete
Water saturated concrete
Permissible Drilling Method
Hammer drilling with carbide tipped drill bit
Hilti TE-CD or TE-YD Hollow Drill Bit
Table 56 — Hilti HIS-N and HIS-RN specifications
Setting information Symbol Units
Thread size 3 / 8-16 UNC 1 / 2-13 UNC 5 / 8-11 UNC 3 / 4-10 UNC
Outside diameter of insert
in .
0.65
0.81
1.00
1.09
Nominal bit diameter
d o
in .
11 / 16
7 / 8
1-1 / 8
1-1 / 4
Effective embedment
h ef
in .
( mm )
4-3 / 8
( 110 )
5
( 125 )
6-3 / 4
( 170 )
8-1 / 8
( 205 )
Thread engagement
minimum maximum
h s
in . in .
3 / 8
15 / 16
1 / 2
1-3 / 16
5 / 8
1-1 / 2
3 / 4
1-7 / 8
Installation torque
T inst
ft-lb
( Nm )
15
( 20 )
30
( 40 )
60
( 81 )
100
( 136 )
Minimum concrete thickness
h min
in .
( mm )
5.9
( 150 )
6.7
( 170 )
9.1
( 230 )
10.6
( 270 )
Minimum edge distance
c min
in
( mm )
3-1 / 4
( 83 )
4
( 102 )
5
( 127 )
5-1 / 2
( 140 )
Minimum anchor spacing
s min
in
( mm )
3-1 / 4
( 83 )
4
( 102 )
5
( 127 )
5-1 / 2
( 140 )
Figure 13 — Hilti HIS-N and HIS-RN specifications
68 Anchor Fastening Technical Guide Edition 22 | 3.0 ANCHORING SYSTEMS | 3.2.2 HILTI HIT-HY 200 A / R V3 Hilti , Inc . 1-800-879-8000 | en español 1-800-879-5000 | www . hilti . com | Hilti ( Canada ) Corporation | www . hilti . ca | 1-800-363-4458