Product Technical Guides : US-EN Anchor Fastening - August 2021 | Page 353

Anchor Fastening Technical Guide , Edition 22
Table 32 — Hilti KH-EZ , KH-EZ P , KH-EZ PM , KH-EZ PL , KH-EZ C and KH-EZ CRC allowable loads installed in top-of-grout-filled concrete masonry walls or horizontal members of wall openings 1 , 2 , 3
Nominal anchor diameter in .
1 / 4
3 / 8
1 / 2
Minimum embedment depth in .
1 5 / 8
2 1 / 2
1 5 / 8
3 1 / 4
2 1 / 4
4 1 / 4
5 / 8 5
Edge distance 4 in .
1 1 / 2
Critical spacing 5 in .
Minimum end distance 6 in .
Tension lb
Parallel to edge of masonry wall
Shear lb Load direction
Perpendicular to edge of masonry wall
205 180 135 3 3 / 4 205 275 275
4 4 1 1 / 2 355 345 155
3 3 / 4 390 415 330 1 1 / 2
245 345 175 3 3 / 4 245 345 345
6 6 1 1 / 2 465 490 200
3 3 / 4 540 800 625 1 3 / 4
390 460 200 3 3 / 4 610 525 500
8 8 1 3 / 4 540 885 245
3 3 / 4 750 1275 550 1 3 / 4
975 930 245
10 10 3 3 / 4 975 2190 630
3 / 4 6 1 / 4 3 3 / 4 12 12 975 2430 630
Table 33 — Hilti KH-EZ , KH-EZ P , KH-EZ PM , KH-EZ PL , KH-EZ C and KH-EZ CRC allowable loads installed in end-of-wall or vertical members of wall openings 1 , 2
Nominal anchor diameter in .
1 / 4
3 / 8
1 / 2
Minimum embedment depth in .
1 5 / 8
2 1 / 2
1 5 / 8
3 1 / 4
2 1 / 4
4 1 / 4
Edge distance 4 in .
1 1 / 2
Critical spacing 5 in .
Minimum end distance 6 in .
Tension lb
Parallel to edge of masonry wall
Shear lb Load direction
Perpendicular to edge of masonry wall
360 525 205 3 3 / 4 380 595 585
4 4 1 1 / 2 590 610 225
3 3 / 4 755 635 585 1 1 / 2
355 725 215 3 3 / 4 465 1010 825
6 6 1 1 / 2 565 875 240
3 3 / 4 1020 1195 1050 1 3 / 4
500 855 260 3 3 / 4 525 1100 1050
8 8 1 3 / 4 650 925 280
3 3 / 4 1150 1240 1050 5 / 8 5 3 3 / 4 10 10 1605 2215 1050 3 / 4 6 1 / 4 3 3 / 4 12 12 1865 2550 1050
1 All values are for anchors installed in fully grouted concrete masonry with minimum masonry prism strength of 1,500 psi . Concrete masonry units may be lightweight , medium-weight or normal-weight conforming to ASTM C90 . Allowable loads are calculated using safety factor of 5 .
2 See figure 6 and 7 for allowable anchor installation locations on the top of grout-filled concrete masonry walls . Anchors may not be installed within one inch of a vertical joint . See figure 7 for anchor installation locations in end-of-wall and vertical members of wall openings .
3 Anchors may not be installed within 1-1 / 4 " in any direction of a head joint . 4 For load values at edge distances between listed values linear interpolation is permitted . 5 Critical spacing equals minimum spacing . 6 Minimum end distance applicable to top-of-wall and end-of-wall and does not apply for wall openings such as windows .
3.3.6
Anchor Fastening Technical Guide Edition 22 | 3.0 ANCHORING SYSTEMS | 3.3.6 KWIK HUS-EZ SCREW ANCHOR Hilti , Inc . 1-800-879-8000 | en español 1-800-879-5000 | www . hilti . com | Hilti ( Canada ) Corporation | www . hilti . ca | 1-800-363-4458
349