Product Technical Guides : US-EN Anchor Fastening - August 2021 | Page 336

MATERIAL SPECIFICATIONS
Heat treated carbon steel with a minimum zinc coating of 0.0003 inch ( 8 μm ) thick in accordance with DIN EN ISO 4042 . KH-EZ CRC has mechanically deposited zinc coating with a minimum thickness of 0.0021 inch ( 53 μm ) in accordance with ASTM B695 , Class 55 .
INSTALLATION PARAMETERS
Table 1 — Hilti KH-EZ , KH-EZ P , KH-EZ PM , KH-EZ PL , KH-EZ C and KH-EZ CRC specifications
Setting
information
Symbol
Units
Nominal anchor diameter 1 / 4 3 / 8 1 / 2 5 / 8 3 / 4
Head style and coating
Hex , P , PM , PL , C head
Hex , C head
Hex , C head ( Including CRC )
Hex head ( Including CRC )
Hex head ( Including CRC )
Hex head ( Including CRC )
Nominal bit diameter d bit in . 1 / 4 3 / 8 1 / 2 5 / 8 3 / 4
Minimum nominal embedment
Minimum effective embedment h nom in . 1-5 / 8 2-1 / 2 1-5 / 8 2-1 / 8 2-1 / 2 3-1 / 4 2-1 / 4 3 4-1 / 4 3-1 / 4 4 5 4 6-1 / 4 h ef in . 1.18 1.92 1.11 1.54 1.86 2.50 1.50 2.16 3.22 2.39 3.03 3.88 2.92 4.84
Minimum hole depth h o in . 2 2-7 / 8 1-7 / 8 2-3 / 8 2-3 / 4 3-1 / 2 2-5 / 8 3-3 / 8 4-5 / 8 3-5 / 8 4-3 / 8 5-3 / 8 4-3 / 8 6-5 / 8
Minimum fixture hole diameter d h in . 3 / 8 1 / 2 5 / 8 3 / 4 7 / 8
Anchor Length = h nom
+ t l See ordering information
Installation torque concrete 1 T inst ft-lb ( Nm )
18 ( 24 )
19 ( 26 )
40 ( 54 )
45 ( 61 )
85 ( 115 )
95 4
( 129 )
Maximum impact wrench ft-lb
T torque rating concrete 2 impact , max
( Nm )
157 ( 213 )
157 ( 213 )
450 ( 610 )
137 ( 186 )
450 ( 610 )
590 ( 800 )
590 ( 800 )
Installation torque masonry KH-EZ ( P , PM , PL , C ) 1 T inst ft-lb ( Nm )
21 ( 28 )
22 ( 30 )
34 ( 46 )
38 ( 52 )
70 ( 95 )
Installation torque masonry for KH-EZ CRC 1 T inst ft-lb ( Nm )
20 ( 27 )
25 ( 34 )
35 ( 48 )
45 ( 61 )
Maximum impact wrench torque rating masonry for KH-EZ ( P , PM , PL , C ) 2 , 3 T impact , max
ft-lb ( Nm )
114 ( 155 )
114 ( 155 )
332 ( 450 )
332 ( 450 )
332 ( 450 )
332 ( 450 )
Maximum impact wrench torque rating masonry for KH-EZ CRC 2 , 3 T impact , max ft-lb ( Nm )
100 ( 136 )
100 ( 136 )
332 ( 450 )
332 ( 450 )
Wrench size in . 7 / 16 9 / 16 3 / 4 15 / 16 1-1 / 8 1 T inst is the maximum installation torque that may be applied with a torque wrench . 2 Because of variability in measurement procedures , the published torque of an impact tool may not correlate properly with the above setting torques .
Over torquing can damage the base material , anchor and / or reduce its holding capacity . 3 For more information on KH-EZ installed in masonry , see ESR-3056 and Design Information for Masonry in this section . 4 Maximum installation torque in concrete for 3 / 4-in diameter KH-EZ CRC is 95 ft-lbs . ( 115 Nm ).
Figure 1 — Hilti KH-EZ specifications
DESIGN INFORMATION IN CONCRETE PER ACI 318
ACI 318 Chapter 17 design The load values contained in this section are Hilti Simplified Design Tables . The load tables in this section were developed using the Strength Design parameters and variables of ESR-3027 and the equations within ACI 318 Chapter 17 . For a detailed explanation of the Hilti Simplified Design Tables , refer to section 3.1.8 of the North American Product Technical Guide , Volume 2 : Anchor Fastening Technical Guide , Edition 22 ( PTG Ed . 21 ). Data tables from ESR-3027 are not contained in this section , but can be found at www . icc-es . org or at www . hilti . com .
332 Anchor Fastening Technical Guide Edition 22 | 3.0 ANCHORING SYSTEMS | 3.3.6 KWIK HUS-EZ SCREW ANCHOR Hilti , Inc . 1-800-879-8000 | en español 1-800-879-5000 | www . hilti . com | Hilti ( Canada ) Corporation | www . hilti . ca | 1-800-363-4458