Table 34 — Hilti Carbon Steel KB-TZ2 in the soffit of uncracked lightweight concrete over metal deck , applicable for both hammer and core drilled installations 1 , 2 , 3 , 4 , 5 , 6
Nominal anchor diameter in .
1 / 4
3 / 8
1 / 2
5 / 8
3 / 4
Installation per Figure 4 Installation per Figure 5
Effective embedment in . ( mm )
Nominal embedment in . ( mm )
Min . conc . thickness 8 in . ( mm )
Tension - ФN n
Shear - ФV n = 3,000 psi = 4,000 psi = 3,000 psi f ́c f ́c f ́c
( 20.7 MPa )
( 27.6 MPa )
( 20.7 MPa ) lb ( kN ) lb ( kN ) lb ( kN )
Min . conc . thickness 8 in . ( mm )
Tension - ФN n
Shear - ФV n = 3,000 psi = 4,000 psi = 3,000 psi f ́c f ́c f ́c
( 20.7 MPa )
( 27.6 MPa )
( 20.7 MPa ) lb ( kN ) lb ( kN ) lb ( kN )
1-1 / 2
1-3 / 4
2-1 / 2
775
820
1,060
2-1 / 4
620
655
730
( 38 )
( 44 )
( 64 )
( 3.4 )
( 3.6 )
( 4.7 )
( 57 )
( 2.8 )
( 2.9 )
( 3.2 )
1-1 / 2
1-7 / 8
2-1 / 2
1,205
1,285
880
2-1 / 4
645
685
1,540
( 38 )
( 48 )
( 64 )
( 5.4 )
( 5.7 )
( 3.9 )
( 57 )
( 2.9 )
( 3.0 )
( 6.9 )
2
2-1 / 2
2-1 / 2
1,705
1,830
1,380
2-1 / 4
1,615
1,730
1,630
( 51 )
( 64 )
( 64 )
( 7.6 )
( 8.1 )
( 6.1 )
( 57 )
( 7.2 )
( 7.7 )
( 7.3 )
2-1 / 2
( 64 )
3
( 76 )
2-1 / 2
( 64 )
1,945
( 8.7 )
2,155
( 9.6 )
1,380
( 6.1 )
N / A
N / A
N / A
N / A
1-1 / 2
2
2-1 / 2
1,205
1,390
1,165
2-1 / 4
1,180
1,365
1,740
( 38 )
( 51 )
( 64 )
( 5.4 )
( 6.2 )
( 5.2 )
( 57 )
( 5.2 )
( 6.1 )
( 7.7 )
2
2-1 / 2
2-1 / 2
1,790
2,015
1,470
2-1 / 4
1,235
1,395
2,065
( 51 )
( 64 )
( 64 )
( 8.0 )
( 9.0 )
( 6.5 )
( 57 )
( 5.5 )
( 6.2 )
( 9.2 )
2-1 / 2
( 64 )
3
( 76 )
2-1 / 2
( 64 )
2,435
( 10.8 )
2,645
( 11.8 )
2,135
( 9.5 )
N / A
N / A
N / A
N / A
3-1 / 4
3-3 / 4
2-1 / 2
3,065
3,390
2,755
3-1 / 4
1,730
1,915
2,250
( 83 )
( 95 )
( 64 )
( 13.6 )
( 15.1 )
( 12.3 )
( 83 )
( 7.7 )
( 8.5 )
( 10.0 )
2-3 / 4
3-1 / 4
2-1 / 2
2,870
3,315
2,480
3-1 / 4
1,925
2,225
2,655
( 70 )
( 83 )
( 64 )
( 12.8 )
( 14.7 )
( 11.0 )
( 83 )
( 8.6 )
( 9.9 )
( 11.8 )
4
( 102 )
4-1 / 2
( 114 )
2-1 / 2
( 64 )
3,780
( 16.8 )
4,365
( 19.4 )
3,025
( 13.5 )
N / A
N / A
N / A
N / A
3-1 / 4
4
2-1 / 2
2,470
2,730
2,655
( 83 )
( 102 )
( 64 )
( 11.0 )
( 12.1 )
( 11.8 )
N / A
N / A
N / A
N / A
3-3 / 4 9
4-1 / 2
3-1 / 4
3,115
3,405
5,110
( 95 )
( 114 )
( 83 )
( 13.9 )
( 15.1 )
( 22.7 )
N / A N / A N / A N / A
3.3.5
Table 35 — Hilti Carbon Steel KB-TZ2 in the soffit of cracked lightweight concrete over metal deck , applicable for both hammer and core drilled installations 1 , 2 , 3 , 4 , 5 , 6 , 7
Nominal anchor diameter in .
1 / 4
3 / 8
1 / 2
5 / 8
3 / 4
Installation per Figure 4 Installation per Figure 5
Effective embedment in . ( mm )
Nominal embedment in . ( mm )
Min . conc . thickness 8 in . ( mm )
Tension - ФN n
Shear - ФV n = 3,000 psi = 4,000 psi = 3,000 psi f ́c f ́c f ́c
( 20.7 MPa )
( 27.6 MPa )
( 20.7 MPa ) lb ( kN ) lb ( kN ) lb ( kN )
Min . conc . thickness 8 in . ( mm )
Tension - ФN n
Shear - ФV n = 3,000 psi = 4,000 psi = 3,000 psi f ́c f ́c f ́c
( 20.7 MPa )
( 27.6 MPa )
( 20.7 MPa ) lb ( kN ) lb ( kN ) lb ( kN )
1-1 / 2
1-3 / 4
2-1 / 2
230
260
1,060
2-1 / 4
185
205
730
( 38 )
( 44 )
( 64 )
( 1.0 )
( 1.2 )
( 4.7 )
( 57 )
( 0.8 )
( 0.9 )
( 3.2 )
1-1 / 2
1-7 / 8
2-1 / 2
1,055
1,220
880
2-1 / 4
565
650
1,540
( 38 )
( 48 )
( 64 )
( 4.7 )
( 5.4 )
( 3.9 )
( 57 )
( 2.5 )
( 2.9 )
( 6.9 )
2
2-1 / 2
2-1 / 2
1,490
1.705
1,380
2-1 / 4
1,385
1,580
1,630
( 51 )
( 64 )
( 64 )
( 6.6 )
( 7.6 )
( 6.1 )
( 57 )
( 6.2 )
( 7.0 )
( 7.3 )
2-1 / 2
( 64 )
3
( 76 )
2-1 / 2
( 64 )
1,565
( 7.0 )
1.695
( 7.5 )
1,380
( 6.1 )
N / A
N / A
N / A
N / A
1-1 / 2
2
2-1 / 2
1,075
1.230
1,165
2-1 / 4
960
1,100
1,740
( 38 )
( 51 )
( 64 )
( 4.8 )
( 5.5 )
( 5.2 )
( 57 )
( 4.3 )
( 4.9 )
( 7.7 )
2
2-1 / 2
2-1 / 2
1,390
1.600
1,470
2-1 / 4
960
1,110
2,065
( 51 )
( 64 )
( 64 )
( 6.2 )
( 7.1 )
( 6.5 )
( 57 )
( 4.3 )
( 4.9 )
( 9.2 )
2-1 / 2
( 64 )
3
( 76 )
2-1 / 2
( 64 )
2,130
( 9.5 )
2,435
( 10.9 )
2,135
( 9.5 )
N / A
N / A
N / A
N / A
3-1 / 4
3-3 / 4
2-1 / 2
2,170
2,435
2,755
3-1 / 4
1,230
1,380
2,250
( 83 )
( 95 )
( 64 )
( 9.7 )
( 10.8 )
( 12.3 )
( 83 )
( 5.5 )
( 6.1 )
( 10.0 )
2-3 / 4
3-1 / 4
2-1 / 2
2,555
2,950
2,480
3-1 / 4
1,715
1,980
2,655
( 70 )
( 83 )
( 64 )
( 11.4 )
( 13.1 )
( 11.0 )
( 83 )
( 7.6 )
( 8.8 )
( 11.8 )
4
( 102 )
4-1 / 2
( 114 )
2-1 / 2
( 64 )
2,855
( 12.7 )
3,300
( 14.7 )
3,025
( 13.5 )
N / A
N / A
N / A
N / A
3-1 / 4
4
2-1 / 2
2,160
2,395
2,655
( 83 )
( 102 )
( 64 )
( 9.6 )
( 10.7 )
( 11.8 )
N / A
N / A
N / A
N / A
3-3 / 4
4-1 / 2
3-1 / 4
2,425
2,735
5,110
( 95 )
( 114 )
( 83 )
( 10.8 )
( 12.2 )
( 22.7 )
N / A N / A N / A N / A
1 See Section 3.1.8 to convert design strength value to ASD value . 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted . 3 Tabular value is for one anchor per flute . Minimum spacing along the length of the flute is 3 x h ef
( effective embedment ).
4 Tabular values are lightweight concrete and no additional reduction factor is needed . 5 No additional reduction factors for spacing or edge distance need to be applied . 6 Comparison of the tabular values to the steel strength is not necessary . Tabular values control . 7 Tabular values are for static loads only . Seismic design is not permitted for uncracked concrete . For seismic tension loads , multiply cracked concrete tabular values in tension only by α N , seis
=
0.75 , except for 3 / 4 x 4-3 / 4 h ef where α N , seis
= 0.73 . See Section 3.1.8 for additional information on seismic applications . 8 Minimum concrete thickness over the upper flute when anchor is installed in the lower flute . See Figure 4 and 5 . 9 For core drilled installations of 3 / 4 “ anchors installed at 3-3 / 4 “ effective embedment , apply a reduction factor of 0.89 to the design tension strength of anchors installed in uncracked concrete .
Anchor Fastening Technical Guide Edition 22 | 3.0 ANCHORING SYSTEMS | 3.3.5 KWIK BOLT TZ2 EXPANSION ANCHOR Hilti , Inc . 1-800-879-8000 | en español 1-800-879-5000 | www . hilti . com | Hilti ( Canada ) Corporation | www . hilti . ca | 1-800-363-4458
317