Product Technical Guides : US-EN Anchor Fastening - August 2021 | Page 196

INSTALLATION INSTRUCTIONS
Installation Instructions For Use ( IFU ) are included with each product package . They can also be viewed or downloaded online at www . hilti . com . Because of the possibility of changes , always verify that downloaded IFU are current when used . Proper installation is critical to achieve full performance . Training is available on request . Contact Hilti Technical Services for applications and conditions not addressed in the IFU .
Figure 13 — Influence of in-service temperature on bond loads 120
% of Allowable load bond values @ 70 ° F
110
100
90
80
70
60
50
100 % 100 % 100 %
98 %
80 % 74 %
56 %
40 0 20 40 60 80 100 120 140 160 180 200
Base material temperature , ° F
192 Anchor Fastening Technical Guide Edition 22 | 3.0 ANCHORING SYSTEMS | 3.2.4 HIT-HY 270 HYBRID FOR MASONRY CONSTRUCTION Hilti , Inc . 1-800-879-8000 | en español 1-800-879-5000 | www . hilti . com | Hilti ( Canada ) Corporation | www . hilti . ca | 1-800-363-4458