Product Technical Guides : US-EN Anchor Fastening - August 2021 | Page 195

Anchor Fastening Technical Guide , Edition 22
HIT-HY 270 adhesive with Hilti HAS threaded rods
Hilti HAS threaded rod
Permissible Base
Materials
Hollow core concrete
Permissible drilling method
Rotary only drilling with carbide tipped drill bit
Hilti TE-CD or TE-YD Hollow Drill Bit
3.2.4
Table 18 — Hilti HIT-HY 270 allowable adhesive bond loads for threaded rods in hollow core concrete panels 1 , 4 , 5 , 6
Nominal anchor diameter in .
Effective embedment in . ( mm ) 2
Minimum concrete thickness in . ( mm ) 3
Tension lb ( kN )
Shear lb ( kN )
3 / 8 2 ( 50.8 ) 1-3 / 8 ( 34.9 ) 450 ( 2.0 ) 560 ( 2.5 )
1 All values are for anchor installed in hollow core concrete with minimum compressive strength of 7,000 psi . Due to variations in materials and dimensional configurations , on-site testing is required to determine the actual performance of the anchor . Allowable loads are calculated using a safety factor of 5 .
2 Tabulated embedment depth is limited by the plastic HIT-SC 16x50 mm screens . See Figure 12 .
3 The required concrete thickness is the thickness for which values are available and installation is recommended . Anchors shall be installed along the centerline of the hollow core or along the line of minimum thickness . Verify these requirements with the hollow core plank supplier before installation . The required thickness is measured from the inner to the outer side of hollow core panel . See Figure 12 .
4 Tabulated allowable loads must be the lesser of the adjusted bond values tabulated and the steel values in table 3 . 5 Allowable loads shall be adjusted for increased base material temperature in accordance with Figure 13 . 6 For combined loading : ( T applied
/ T allowable ) + ( V applied
/ V allowable ) ≤ 1
Figure 12 — Hilti HIT-HY 270 adhesive installed in hollow core concrete 1 , 2
1 Representation of the tested conditions for which allowable adhesive bond loads are applicable . Refer to footnote 3 of corresponding load table above for more information on requirements and restrictions on the admissible anchor installation .
2 Minimum edge distance is 6-inches . Minimum spacing is :
- 8-inches along the length of each hollow core section .
- One anchor per hollow core section ( left and right on page ), 6-inches minimum between adjacent hollow core sections .
Anchor Fastening Technical Guide Edition 22 | 3.0 ANCHORING SYSTEMS | 3.2.4 HIT-HY 270 HYBRID FOR MASONRY CONSTRUCTION Hilti , Inc . 1-800-879-8000 | en español 1-800-879-5000 | www . hilti . com | Hilti ( Canada ) Corporation | www . hilti . ca | 1-800-363-4458
191