Product Technical Guides : US-EN Anchor Fastening - August 2021 | Page 108

INSTALLATION INSTRUCTIONS
Installation Instructions For Use ( IFU ) are included with each product package . They can also be viewed or downloaded online at www . hilti . com . Because of the possibility of changes , always verify that downloaded IFU are current when used . Proper installation is critical to achieve full performance . Training is available on request . Contact Hilti Technical Services for applications and conditions not addressed in the IFU .
MATERIAL SPECIFICATIONS
Figure 15 — Hilti HIT-HY 200 A / R V3 adhesive cure time and working time ( approx .)
1 It is permitted to install Hilti HIT-HY 200 V3 with HIT-Z anchor rod down to 14 ° F ( -10 ° C ) provided the drilled hole has the drilling dust fully removed . This can be done with Hilti TE-CD or TE-YD hollow drill bit or with cleaning procedures used with standard threaded rod .
Resistance of cured Hilti HIT-HY 200 A / R V3 to chemicals
Chemical Behavior
Acetic acid
10 %
+
Acetone
Ammonia
5 %
+
Benzyl alcohol
Hydrochloric acid
10 %
Chlorinated lime
10 %
+
Citric acid
10 %
+
Concrete plasticizer
+
De-icing salt ( Calcium chloride )
+
Demineralized water
+
Diesel fuel
+
Drilling dust suspension pH 13.2
+
Ethanol
96 %
Ethylacetate
Formic acid
10 %
+
Formwork oil
+
Gasoline
+
Glycole
Hydrogen peroxide
10 %
Lactic acid
10 %
+
Maschinery oil
+
Methylethylketon
Nitric acid
10 %
Phosphoric acid
10 %
+
Potassium Hydroxide pH 13.2
+
Sea water
+
Sewage sludge
+
Sodium carbonate 10 %
10 %
+
Sodium hypochlorite 2 %
2 %
+
Sulphuric acid
10 %
30 %
+
+
Toluene
Xylene
Key :
– non-resistant + resistant ▯ limited resistance
Samples of the HIT-HY 200 A / R V3 adhesive were immersed in the various chemical compounds for up to one year . At the end of the test period , the samples were analyzed . Any samples showing no visible damage and having less than a 25 % reduction in bending ( flexural ) strength were classified as “ Resistant .” Samples that had slight damage , such as small cracks , chips , etc . or reduction in bending strength of 25 % or more were classified as “ Limited Resistance ” ( i . e . exposed for 48 hours or less until chemical is cleaned up ). Samples that were heavily damaged or destroyed were classified as “ Non-Resistant .”
Note : In actual use , the majority of the adhesive is encased in the base material , leaving very little surface area exposed .
104 Anchor Fastening Technical Guide Edition 22 | 3.0 ANCHORING SYSTEMS | 3.2.2 HILTI HIT-HY 200 A / R V3 Hilti , Inc . 1-800-879-8000 | en español 1-800-879-5000 | www . hilti . com | Hilti ( Canada ) Corporation | www . hilti . ca | 1-800-363-4458