Product Technical Guides : US-EN Anchor Fastening - August 2021 | Page 219

Anchor Fastening Technical Guide , Edition 22
HIT-ICE with HIS-N Inserts
Figure 6 - Hilti HIS-N and HIS-RN internally threaded insert installation conditions
Permissible concrete conditions
Uncracked concrete
Cracked concrete
Dry concrete
Water saturated concrete
Permissible Drilling Method
Hammer drilling with carbide tipped drill bit
Hilti TE-CD or TE-YD Hollow Drill Bit
3.2.5
Table 31 — Hilti HIS-N and HIS-RN installation specifications
Setting information
Symbol
Units
3 / 8-16 UNC
Thread size
1 / 2-13 UNC
5 / 8-11 UNC
3 / 4-10 UNC
Outside diameter of insert
in .
0.65
0.81
1.00
1.09
Nominal bit diameter
d o
in .
11 / 16
7 / 8
1-1 / 8
1-1 / 4
Effective embedment
h ef
in .
( mm )
4-3 / 8
( 110 )
5
( 125 )
6-3 / 8
( 170 )
8-1 / 8
( 205 )
Thread engagement
minimum maximum
h s
in . in .
3 / 8
15 / 16
1 / 2
1-3 / 16
5 / 8
1-1 / 2
3 / 4
1-7 / 8
Installation torque
T inst
ft-lb
( Nm )
15
( 20 )
30
( 40 )
60
( 81 )
100
( 136 )
Minimum concrete thickness
h min
in .
( mm )
5.9
( 150 )
6.7
( 170 )
9.1
( 230 )
10.6
( 270 )
Figure 7 — HIS-N and HIS-RN specifications
Anchor Fastening Technical Guide Edition 22 | 3.0 ANCHORING SYSTEMS | 3.2.5 HIT-ICE ADHESIVE ANCHORING SYSTEM Hilti , Inc . 1-800-879-8000 | en español 1-800-879-5000 | www . hilti . com | Hilti ( Canada ) Corporation | www . hilti . ca | 1-800-363-4458
215