Product Technical Guides : CA-EN Steel Deck Fastening Systems | Page 7

Steel Deck Fastening Systems Steel Deck Fastener Design and Selection 1.1 Figure 2: Small Element Connection Tests 2. Full Scale Diaphragm System Tests Full scale diaphragm system tests are used to determine the strength and stiffness of a larger steel deck diaphragm assembly directly. The data is analyzed and fit in a predictive model to address varying configurations of base steel, steel deck, specific fastener combinations and spans. These tests are conducted in accordance with the following standards and shown in Figures 3, 4 and 5. • ICC-ES AC43 Acceptance Criteria for Steel Deck Roof and Floor Systems • AISI S907 Cantilever Test Method for Cold-Formed Steel Diaphragms • ASTM E455 Standard Test Method for Static Load Testing of Framed Floor or Roof Diaphragm Constructions for Buildings Figure 3: ICC-ES AC43 Diaphragm Test Frame Schematics 30 '-0 " " 24'-0 Figure 4: AC43 Diaphragm Test Frame Fastening Systems Research Laboratory (FSRL), Schaan, Liechtenstein Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 5