Product Technical Guides : CA-EN Steel Deck Fastening Systems | Page 65

Steel Deck Fastening Systems X-HVB Shear Connector 1.7 1.7.4 Connector Positioning Connector positioning (metal decking ribs transverse to beam) 1. One to three X-HVB’s per rib. = = 2. X-HVB’s transverse or parallel to beam. ≥  1-9/16" 40 ≥  1-9/16" 40 = Wr ≥1-9/16" Wr ≥1-9/16" 3. With one X-HVB per rib, the leg may be either centered in the rib or positioned to give a 1-9/16" (40 mm) clearance to the side of the rib. ≥ 2"  50 = ≥ 50 2"  ≥ 100 4"  ≤ 2" 5b. S  pacings along the ribs (other decking profiles) ≥ 100 4"  Minimum spacing ≥ 2" (50 mm), however for decking profiles with: w r /m < 0.7 and w r /h r < 1.8, the minimum spacing is increased from 2" to 4" (50 to 100 mm). > > 4" 100  51 4. With two or three X-HVB’s per rib, the legs may be either centered in the rib or alternated about the center. m = spacing of ribs 5a. Spacing along the ribs (2" and 3" U.S. composite floor deck profiles) 6. If the decking has a stiffener in the rib bottom, position the X-HVB’s against the stiffener. Connector positioning (ribs parallel to beam and solid slabs) X-HVB’s may be placed with zero clearance to edge of flange. 50 ≥  2" ≤ 4Y or 24" con or 600  4 d  ≥ 100 4" 1.7.5 Ordering Information X-HVB Shear Connectors* Description Qty/Pkg X-HVB80 X-HVB95 X-HVB110 X-HVB125 250 250 250 200 Setting Equipment for X-HVB Shear Connectors Description DX-76 X-76-F-HVB Baseplate X-76-P-HVB Piston X-76-PS Stop Ring * X-HVB shear connectors must be fastened with the X-76-F-HVB fastener guide, the X-76-P-HVB piston and the X-ENP-21 HVB fastener. Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 63