Product Technical Guides : CA-EN Steel Deck Fastening Systems | Page 63

Steel Deck Fastening Systems X-HVB Shear Connector 1.7 1.7.1 Product Description Guide specification The Hilti X-HVB Shear Connector is a mechanically attached shear transfer device for use in composite beam construction with steel beams and concrete slabs as an alternate to welded studs. Shear connector: Shear connectors shall be one piece formed steel with zinc plating in accordance with ASTM B633 SC 1 Type III. Connectors shall be Hilti X-HVB as supplied by Hilti Inc. Product features • Ductile connections • Minimal damage to coatings • Fast and simple installation • Install in virtually any weather • No electrical power source required 1.7.1 Product Description 1.7.2 Material Specifications 1.7.3 Technical Data 1.7.4 Connector Positioning 1.7.5 Ordering Information Installation: Shear connectors shall be installed using Hilti X-ENP-21 HVB powder-actuated fasteners in accordance with manufacturer’s recommendation. (Note: Do not use X-ENP-19 L15.) 1.7.2 Material Specification X-HVB: Carbon Steel with F u = 39,000 psi Zinc plated for corrosion resistance in accordance with ASTM B633, SC 1, Type III. Reference Section 2.3.3.1 of Hilti North American Product Technical Guide Volume 1: Direct Fastening for more information. 1.7.3 Technical Data Product selection and performance in concrete over metal deck composite floor slabs 3 X-HVB connector X-HVB80 X-HVB95 X-HVB110 X-HVB125 X-HVB140 Connector height, H s in. (mm) Minimum slab thickness, Y con in. (mm) Maximum rib height, h r in. (mm) w r /h r ≥ 1.8 w r /h r < 1.8 3-1/8 3-11/16 1-3/4 1-3/4 6294 3147 (80) (93) (45) (45) (28.0) (14.0) 3-3/4 4-1/4 2-3/8 2-1/4 (95) (108) (60) (57) 4-5/16 4-13/16 2-15/16 2-5/8 (110) (123) (75) (66) 7868 3934 4-15/16 5-7/16 3-1/8 2-15/16 (35.0) (17.5) (125) (138) (80) (75) 5-1/2 6 3-1/8 3-1/8 (140) (152) (80) (80) Nominal shear strength 1 , Q n lb (kN) Allowable shear strength 2 , q lb (kN) 1 Nominal shear strength to be used for designs per AISC-LRFD and unfactored shear resistance per AISC design formulas. 2 Allowable shear strength to be used for designs per AISC-ASD. 3 Tabulated load values based upon installation in base steel greater than or equal to 5/16". Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 61