Product Technical Guides : CA-EN Steel Deck Fastening Systems | Page 44
Steel Deck Fastening Systems
1.3 X-ENP-19 for Fastening Deck to Structural Steel
c
Limit States Design-Factored resistance diaphragm tables for deck fasteners (Canada)
Diaphragm Table 36-7
w/X-ENP-19 L15 Metric
Limit States Design (LSD)-Factored Resistance Diaphragm Shear, q, (N / mm) and Flexibility Factor, F, (mm x 10 -6 / N)
for 38 mm deep steel nestable deck fastened with Hilti X-ENP-19 L15 with screwed sidelaps (Canada only) 1, 2, 3
No. of transverse nails per 900 mm wide deck units=7 (every flute)
Sidelap Connection
#12 screw at 600 mm O.C. #12 screw at 450 mm O.C. #12 screw at 300 mm O.C. #12 screw at 150 mm O.C.
Span (mm)
22
20
18
16
22
20
18
16
22
20
18
16
22
20
18
16
Deck gauge thickness
Strength, S LSD
7.1
8.5
11.2 13.9
7.1
8.5
11.2 13.9
9.2
11.0 14.6 18.2 12.8 15.4 20.3 25.4
1200
Flexibility Factor, F
109
78
51
38
109
78
51
38
104
74
47
34
99
69
43
30
Strength, S LSD
5.6
8.5
8.9
11.3
6.7
8.0
10.6 13.2
8.5
10.2 13.4 16.8 12.2 14.7 19.4 24.3
1500
Flexibility Factor, F
102
75
52
39
98
72
49
37
93
68
45
33
87
62
40
29
Strength, S LSD
5.5
6.7
8.8
11.0
6.3
7.8
10.2 12.7
7.9
9.5
12.6 15.7 11.8 14.2 18.8 23.5
1800
Flexibility Factor, F
94
71
50
38
91
68
47
36
86
64
44
33
79
57
38
28
Strength, S LSD
4.7
5.6
7.5
9.4
5.4
6.6
8.7
10.9
7.5
9.2
12.0 15.0 11.5 13.9 18.3 22.9
2100
Flexibility Factor, F
93
72
52
41
89
68
49
38
82
61
43
33
74
54
37
27
Strength, S LSD
4.7
5.8
7.6
9.5
5.4
6.5
8.6
10.8
7.3
8.7
11.5 14.5 11.3 13.6 18.0 22.6
2400
Flexibility Factor, F
89
69
50
40
85
66
48
38
78
60
42
33
70
52
35
27
Strength, S LSD
4.2
5.1
6.7
8.5
5.3
6.5
8.6
10.8
7.1
8.5
11.2 14.0 11.0 13.4 17.6 22.2
2700
Flexibility Factor, F
89
70
52
42
82
64
47
37
76
58
42
33
66
50
35
26
Strength, S LSD
4.2
5.2
6.8
8.6
4.8
5.8
7.6
9.6
6.8
8.2
10.9 13.6 10.9 13.3 17.4 21.9
3000
Flexibility Factor, F
86
68
51
42
82
65
49
39
73
57
41
33
64
48
34
26
Diaphragm Table 36-4
w/X-ENP-19 L15 Metric
Limit States Design (LSD)-Factored Resistance Diaphragm Shear, q, (N / mm) and Flexibility Factor, F, (mm x 10 -6 / N)
for 38 mm deep steel nestable deck fastened with Hilti X-ENP-19 L15 with screwed sidelaps (Canada only) 1, 2, 3
No. of transverse nails per 900 mm wide deck units=4 (every flute)
Sidelap Connection
#12 screw at 600 mm O.C. #12 screw at 450 mm O.C. #12 screw at 300 mm O.C. #12 screw at 150 mm O.C.
Span (mm)
22
20
18
16
22
20
18
16
22
20
18
16
22
20
18
16
Deck gauge thickness
Strength, S LSD
5.1
6.1
8.0
10.0
5.1
6.1
8.0
10.0
6.7
8.1
10.7 13.4
8.8
10.7 14.0 17.5
1200
Flexibility Factor, F
582
372
200
123
582
372
200
123
573
364
193
117
565
357
187
111
Strength, S LSD
4.2
5.1
6.7
8.3
5.1
6.1
8.0
10.0
6.3
7.8
10.2 12.7
8.7
10.5 13.7 17.2
1500
Flexibility Factor, F
483
313
173
110
477
307
168
105
469
300
162
100
460
292
155
94
Strength, S LSD
4.3
5.2
6.8
8.6
4.9
6.0
7.9
9.9
6.1
7.4
9.8
12.2
8.6
10.3 13.5 16.9
1800
Flexibility Factor, F
413
270
151
98
407
265
147
94
400
258
141
89
390
249
134
82
Strength, S LSD
3.6
4.5
6.0
7.5
4.3
5.3
6.9
8.7
6.0
7.3
9.5
11.9
8.5
10.2 13.4 16.8
2100
Flexibility Factor, F
368
244
141
93
362
238
136
89
351
228
127
81
340
219
119
74
Strength, S LSD
3.9
4.7
6.2
7.8
4.5
5.4
7.1
8.8
5.9
7.1
9.3
11.6
8.3
10.1 13.3 16.7
2400
Flexibility Factor, F
329
220
128
86
324
215
124
82
314
206
116
75
303
196
107
67
Strength, S LSD
3.4
4.1
5.5
6.9
4.5
5.4
7.2
8.9
5.8
6.9
9.2
11.4
8.3
10.1 13.2 16.6
2700
Flexibility Factor, F
305
206
123
84
294
196
115
77
285
188
107
70
274
178
99
62
Strength, S LSD
3.6
4.3
5.8
7.3
4.1
4.9
6.5
8.1
5.6
6.8
8.9
11.3
8.2
10.0 13.2 16.5
3000
Flexibility Factor, F
280
190
115
79
275
186
111
76
262
174
101
67
251
164
92
59
Diaphragm Table 36-7
w/X-ENP-19 L15 Metric
Limit States Design (LSD)-Factored Resistance Diaphragm Shear, q, (N / mm) and Flexibility Factor, F, (mm x 10 -6 / N)
for 38 mm deep steel deck fastened with Hilti X-ENP-19 L15 w/button punch sidelaps (Canada only) 1, 2, 3
No. of transverse nails per 900 mm wide deck units=7 (every flute)
Sidelap Connection
Button Punch 600 mm O.C. Button Punch 450 mm O.C. Button Punch 300 mm O.C. Button Punch 150 mm O.C.
Span (mm)
22
20
18
16
22
20
18
16
22
20
18
16
22
20
18
16
Deck gauge thickness
Strength, S LSD
6.1
7.5
10.1 12.9
6.1
7.5
10.1 12.9
6.9
8.6
11.9 15.6
8.2
10.5 15.0 20.4
1200
Flexibility Factor, F
113
82
54
40
113
82
54
40
112
81
53
40
110
79
52
38
Strength, S LSD
4.8
6.0
8.1
10.3
5.2
6.5
8.9
11.6
5.8
7.3
10.3 13.9
7.2
9.3
13.6 18.9
1500
Flexibility Factor, F
106
79
55
42
106
79
55
42
105
78
54
41
102
76
52
40
Strength, S LSD
4.2
5.3
7.3
9.6
4.6
5.6
8.0
10.7
5.1
6.5
9.3
12.7
6.6
8.6
12.8 17.9
1800
Flexibility Factor, F
103
79
57
45
103
79
56
44
101
77
55
43
98
75
53
41
Strength, S LSD
3.6
4.5
6.2
8.2
3.9
4.8
6.8
9.2
4.5
5.8
8.5
11.8
6.0
8.0
12.1 17.2
2100
Flexibility Factor, F
103
81
60
48
102
80
59
47
100
78
57
46
96
74
54
43
Strength, S LSD
3.3
4.2
5.9
7.9
3.5
4.5
6.3
8.7
4.1
5.3
7.9
11.0
5.6
7.5
11.5 16.6
2400
Flexibility Factor, F
104
83
62
51
103
82
62
50
101
80
60
49
95
75
56
45
Strength, S LSD
2.9
3.6
5.2
7.1
3.3
4.2
6.1
8.3
3.8
4.9
7.4
10.5
5.3
7.2
11.2 16.1
2700
Flexibility Factor, F
106
86
66
54
104
84
64
53
102
82
63
51
96
76
58
47
Strength, S LSD
2.8
3.5
5.1
6.9
2.9
3.8
5.4
7.5
3.5
4.7
7.1
10.0
5.1
6.9
10.8 15.6
3000
Flexibility Factor, F
108
89
69
57
107
88
68
57
104
84
65
54
96
78
59
49
1 The ratio of span of deck unit to average length of sheet is taken to be 1/3.
2 Diaphragm loads are based on steel decks having an average ultimate tensile strength of 55 ksi.
3 Values shown calculated in accordance with SDI equations using a φ factor of 0.5 for LSD for all load conditions.
Note: Reference pages 40-41 for generally higher diaphragm capacities with Hilti Sidelap Connectors (SLC).
42 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014