Steel Deck Fastening Systems X-HSN 24 for Fastening Deck to Bar Joist 1.2 c Limit States Design-Factored resistance diaphragm tables for deck fasteners (Canada) Diaphragm Table 36-4 with X-HSN 24 Metric Limit States Design (LSD)-Factored Resistance Diaphragm Shear, q, (N/mm) and Flexibility Factor, F, (mm x 10 -6 /N) for 38 mm deep steel deck fastened w/Hilti X-HSN 24 w/button punch sidelaps (Canada only) 1,2,3 No. of transverse nails per 900 mm wide deck units=4 (every other flute) Span (mm) 1200 1500 1800 2100 2400 2700 3000 Sidelap Connection Deck gauge thickness Strength, S LSD Button Punch 600 mm O.C. Button Punch 450 mm O.C. Button Punch 300 mm O.C. Button Punch 150 mm O.C. 22 20 18 16 22 20 18 16 22 20 18 16 22 20 18 16 4.1 4.3 5.7 7.4 3.5 4.3 5.7 7.4 4.0 5.0 7.0 9.3 4.8 6.2 8.9 12.0 Flexibility Factor, F Strength, S LSD 612 399 224 144 612 399 224 144 607 395 220 141 599 388 214 135 3.3 4.0 5.5 7.2 3.5 4.5 6.2 8.1 4.1 5.2 7.4 10.0 5.3 6.8 9.9 13.6 Flexibility Factor, F Strength, S LSD 521 348 203 137 518 345 201 134 513 340 196 130 502 330 188 123 2.9 3.6 5.2 6.9 3.2 4.1 5.9 7.9 3.6 4.7 6.9 9.4 4.9 6.5 9.5 13.2 Flexibility Factor, F Strength, S LSD 462 315 190 132 459 311 188 130 452 306 183 125 438 293 172 116 2.5 3.2 4.5 6.0 2.7 3.8 4.9 6.8 3.3 4.5 6.5 8.9 4.7 6.1 9.2 12.9 Flexibility Factor, F Strength, S LSD 426 297 186 134 422 293 183 131 412 283 175 124 394 268 161 111 2.4 2.9 4.3 6.0 2.5 3.5 4.8 6.7 3.1 4.1 6.2 8.6 4.5 5.9 8.9 12.7 Flexibility Factor, F Strength, S LSD 398 282 182 134 394 278 179 131 383 268 170 123 362 249 154 109 2.0 2.6 3.8 5.3 2.4 3.4 4.7 6.6 2.9 3.9 6.0 8.3 4.2 5.8 8.8 12.5 Flexibility Factor, F Strength, S LSD 382 276 184 139 373 268 177 132 361 257 168 124 337 236 149 107 2.0 2.6 3.8 5.3 2.1 3.2 4.2 6.0 2.7 3.6 5.8 8.1 4.1 5.6 8.7 12.3 Flexibility Factor, F 367 393 183 140 362 265 180 137 346 250 166 125 318 225 145 106 Diaphragm Table 24-5 with X-HSN 24 Metric Limit States Design (LSD)-Factored Resistance Diaphragm Shear, q, (N/mm) and Flexibility Factor, F, (mm x 10 -6 /N) for 75 mm deep steel deck fastened with Hilti X-HSN 24 w/button punch sidelaps (Canada only) 1, 2, 3 No. of transverse nails per 600 mm wide deck units=5 (every flute) Span (mm) 2400 2700 1800 3300 3600 3900 4200 Sidelap Connection Deck gauge thickness Strength, S LSD Flexibility Factor, F Strength, S LSD Flexibility Factor, F Strength, S LSD Flexibility Factor, F Strength, S LSD Flexibility Factor, F Strength, S LSD Flexibility Factor, F Strength, S LSD Flexibility Factor, F Strength, S LSD Flexibility Factor, F Button Punch 600 mm O.C. Button Punch 450 mm O.C. Button Punch 300 mm O.C. Button Punch 150 mm O.C. 22 20 18 16 22 20 18 16 22 20 18 16 22 20 18 16 2.0 2.6 3.7 5.2 2.1 2.8 4.2 5.8 2.6 3.5 5.4 7.8 3.9 5.4 8.8 12.9 281 227 173 143 275 222 169 139 262 209 158 130 235 185 137 111 1.7 2.2 3.3 4.5 2.0 2.6 4.0 5.7 2.4 3.3 5.1 7.5 3.7 5.2 8.5 12.6 290 238 185 154 279 227 176 146 264 214 165 136 233 186 140 115 1.6 2.1 3.2 4.5 1.7 2.3 3.5 5.1 2.3 3.1 4.9 7.2 3.6 5.0 8.2 12.4 295 244 192 161 289 238 187 157 268 220 171 143 233 188 143 118 1.4 1.9 2.9 4.1 1.7 2.2 3.5 5.0 2.1 2.9 4.7 7.0 3.4 4.8 8.0 12.2 307 257 205 173 293 245 194 164 272 225 177 149 233 189 146 121 1.4 1.9 2.9 4.1 1.6 2.2 3.4 5.0 2.0 2.8 4.5 6.8 3.3 4.7 7.9 12 312 263 211 180 299 251 201 170 277 231 183 155 233 191 149 124 1.2 1.7 2.6 3.8 1.4 2.0 3.1 4.6 1.9 2.7 4.4 6.6 3.2 4.6 7.8 11.9 325 276 224 191 311 263 212 181 282 237 189 160 234 193 152 127 1.2 1.6 2.6 3.8 1.4 1.9 3.1 4.6 1.9 2.6 4.3 6.5 3.2 4.5 7.6 11.8 331 282 230 197 316 269 218 186 287 242 195 166 235 195 154 129 1 The ratio of span of deck unit to average length of sheet is taken to be 1/3. 2 Diaphragm loads are based on steel decks having an average ultimate tensile strength of 55 ksi. 3 Values shown calculated in accordance with SDI equations using a φ factor of 0.5 for LSD for all load conditions. Note: Reference pages 30-31 for generally higher diaphragm capacities with Hilti Sidelap Connectors (SLC). Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I PTG Decking Supplement 2014 33