Product Technical Guides : CA-EN Cast-In Anchor Channel Fastening Technical Guide | Page 90

1. Anchor Channel Systems 2. HAC Portfolio 3. HAC Applications 4. Design Introduction 5. Base material 6. Loading Criteria Coefficient for pryout strength HAC-40 F HAC-50 F HAC-60 F α ch,V lb 1/2 /in 1/3 (N 1/2 /mm 1/3 ) 10.50 (7.50) k cp - 2 ϕ - Condition A: 0.75 Condition B: 0.70 HAC-70 F 10. Design Software 11. Best Practices 12. Instructions for Use 14. Design Example 13. Field Fixes 2.3.3 H  AC CRFoS U STRUCTURAL STEEL PERFORMANCE — TENSION Table 2.3.3.1 — T  ension steel strength design information for HAC CRFoS U with Hilti Channel Bolts (HBC-C and HBC-C-N) Criteria Symbol Units HAC-50 F CRFoS U HAC-60 F CRFoS U HAC-70 F CRFoS U N sl lb (kN) 7,531 (33.5) 10,723 (47.7) 14,365 (63.9) N sl,seis lb (kN) 7,531 (33.5) 10,723 (47.7) 14,365 (63.9) ϕ - N sa lb (kN) 7,531 (33.5) 11,510 (51.2) 14,275 (63.5) N sa,seis lb (kN) 7,531 (33.5) 11,510 (51.2) 14,275 (63.5) ϕ - Nominal tensile steel strength of connection between anchor and channel N sc lb (kN) 7,531 (33.5) 10,723 (47.7) 14,275 (63.5) Nominal tensile steel strength of connection between anchor and channel for seismic design N sc,seis lb (kN) 7,531 (33.5) 10,723 (47.7) 14,275 (63.5) ϕ - Nominal tensile steel strength for local failure of channel lips Strength reduction factor for local failure of channel lips Symbol HAC-60 F M12 2 lb (kN) 1,920 (8.5) M16 lb (kN) 4,420 (19.7) M20 lb (kN) Strength reduction factor for anchor failure 1,920 (8.5) M16 lb (kN) 4,420 (19.7) M20 lb (kN) Strength reduction factor for failure of connection between anchor and channel 1 5,425 (24.1) N/A Nominal bending strength of the anchor channel with HBC-C M12 Nominal bending strength of the anchor channel for seismic design with HBC-C ϕ M16 - 0.55 M12 M16 lb-in (N*m) 11,903 (1,345) 19,081 (2,156) 26,594 (3,005) lb-in (N*m) 14,125 (1,596) 19,355 (2,187) 28,000 (3,164) lb-in (N*m) 11,903 (1,345) 19,081 (2,156) 26,594 (3,005) - 0.85 1 T  he tabulated value of ϕ applies when both the load combinations of Section 1605.2 of the IBC, ACI 318-14 Section 5.3 or ACI 318-11 Section 9.2 are used and the requirements of ACI 318-14 17.3.3(c) or ACI 318-11 D.4.3(c), as applicable, for Condition B are met. Condition B applies where supplementary reinforcement is not provided. For installations where complying supplementary reinforcement can be verified, the ϕ factors described in ACI 318-14 17.3.3(c) or ACI 318-11 D.4.3(c), as applicable, for Condition A are allowed. Table 3.2.1.2 — Tension concrete strength design information for Hilti Anchor Channels HAC CRFoS U - 0.65 Criteria Units HAC-50 F CRFoS U HAC-60 F CRFoS U HAC-70 F CRFoS U c ac in (mm) 12.52 (318) 17.48 (444) 20.67 (525) ϕ - M20 1 T  he tabulated value of ϕ applies when the load combinations of Section 1605.2 of the IBC, ACI 318-14 Section 5.3 or ACI 318-11 Section 9.2 are used. 2 In case of continuous inspection the value for V sl,x for the size M12 can be taken for all channel sizes HAC-40 F through HAC-70 F as V sl,x = 2,021 lb (9.0 kN). Edge distance required to develop full concrete capacity in absence of anchor reinforcement Strength reduction factor for tension, concrete failure modes 1 Symbol ϕ 0.55 ϕ 28,000 (3,164) Condition A: 0.75 Condition B: 0.70 Cast-In Anchor Channel Product Guide, Edition 1 • 02/2019 91 1 T  he tabulated value of ϕ applies when both the load combinations of Section 1605.2 of the IBC, ACI 318-14 Section 5.3 or ACI 318-11 Section 9.2 are used and the requirements of ACI 318-14 17.3.3(c) or ACI 318-11 D.4.3(c), as applicable, for Condition B are met. Condition B applies where supplementary reinforcement is not provided. For installations where complying supplementary reinforcement can be verified, the ϕ factors described in ACI 318-14 17.3.3(c) or ACI 318-11 D.4.3(c), as applicable, for Condition A are allowed. 90 Strength reduction factor for failure of connection between channel lips and channel bolts 1 (continuous inspection) Strength reduction factor for bending failure M s,flex,seis 19,355 (2,187) M20 Nominal bending strength of the anchor channel for seismic design with HBC-C-N 14,125 (1,596) Strength reduction factor for failure of connection between channel lips and channel bolts 1 (periodic inspection) M s,flex lb-in (N*m) Nominal bending strength of the anchor channel with HBC-C-N 0.75 lb (kN) 0.75 M12 2 Nominal tensile steel strength of a single anchor Nominal tensile steel strength of a single anchor for seismic design 5,425 (24.1) N/A HAC-70 F V sl,x,seis HAC-50 F Nominal shear steel strength of connection between channel lips and channel bolts for seismic design HAC-40 F V sl,x Units Nominal shear steel strength of connection between channel lips and channel bolts Channel bolt type HBC-C-N Criteria 0.75 Table 2.3.2.3 — S  teel strength design information for shear acting in longitudinal direction of the channel axis for Hilti Anchor Channels (HAC) with Hilti Locking Channel Bolts (HBC-C-N) Nominal tensile steel strength for local failure of channel lips for seismic design 1 T  he tabulated value of ϕ applies when both the load combinations of Section 1605.2 of the IBC, ACI 318-14 Section 5.3 or ACI 318-11 Section 9.2 are used and the requirements of ACI 318-14 17.3.3(c) or ACI 318-11 D.4.3(c), as applicable, for Condition B are met. Condition B applies where supplementary reinforcement is not provided. For installations where complying supplementary reinforcement can be verified, the ϕ factors described in ACI 318-14 17.3.3(c) or ACI 318-11 D.4.3(c), as applicable, for Condition A are allowed. Strength reduction factor for shear, concrete failure modes 1 Units 9. Special Anchor Channel Design Factor to account for the influence of channel size and anchor diameter on concrete edge breakout strength in shear Symbol 8. Reinforcing Bar Anchorage Table 2.3.2.2 — S  hear concrete strength design information for Hilti Anchor Channels (HAC) with Hilti Channel Bolts (HBC-C and HBC-C-N) 7. Anchor Channel Design Code