Table 2: fire properties of DuPont Corian products
TM
PROPERTY
®
STANDARD
CLASS/
RESULTS
PRODUCT
Type/Area of
application
*
EN 13501-1
C-s1,d0
Standard grade, all
colours, 6 & 12mm
With any substrate of
A2 or better fire
performance
1
On a substrate with a
fire performance of D
or better.
(wood based substrate)
2
Euroclass for Reaction to fire
Euroclass for Reaction to fire
EN 13501-1
C-s1,d0
Standard grade,
all colours, 12mm
Euroclass for Reaction to fire
EN 13501-1
B-s1,d0
FR grade colours,
12mm
With any substrate of
A2 or better fire
performance
3
Euroclass for Reaction to fire
EN 13501-1
B-s1,d0
FR Grade, GW,
12mm
Applied on aluminium
profiles with a gap of
50mm
4
Euroclass for Reaction to fire
EN 13501-1
B-s1,d0
Standard grade,
GW, 12mm,
930mm wide
Applied on aluminium
profiles with an airgap
and with mineral wool
insulation
5
Euroclass for Reaction to fire
EN 13501-1
B-s1,d0
Glacier Ice, 6mm
(Illumination series)
Installed with an airgap
in the back
6
BS 476 part 6&7
Class 0
FR grade, GW,
12mm
Not specified
(material test)
7
Flammability test
DIN 4102-1
B1
FR Grade,
Genesis colours
With a distance of
>40mm from other
materials
8
Reaction to fire - M Classification
NF P 92-501
M2
Standard Grade,
12mm
Not specified
(material test)
9
Reac tion to fire - M Classification
NF P 92-501
M2
CW, 6mm
Not specified
(material test)
10
Smoke index - F Classification
NF F 16-101
F0
CW, 6 & 12mm
Not specified
(material test)
11
Calorific potential
EN ISO 1716
9.15 KJ/g
12mm, CW
Not specified
(material test)
12
Fire test - Aviation
JAR/FAR - AITM
Pass
FR Grade
Aviation
13
Fire test - Railroad
DIN 5510-2 /
DIN 54837
S 4, SR 2, ST 2
12mm
Railroad vehicle
14
DIN 5510-2 /
EN ISO 5659-2
Pass
12mm
Railroad vehicle
15
Fire behaviour
Smoke toxicity
(1) classification report E131025 from Warrington Fire Research-UK/03-2003
(2) classification report 13126E from Warringtonfiregent-Belgium/02-2008
(3) classification report E131024 from Warrington Fire Research-UK/03-2003
(4) classification report 13448C from Warringtonfiregent-Belgium/12-2008
(5) classification report 13700C from Warringtonfiregent-Belgium/03-2009
(6) classification report 230006665 from MPA NRW-Germany/09-2008
(7) test reports 154054 & 154053 from Warringtonfire-UK/09-2006
(8) test report 230005623 from MPA NRW-Germany/2006
(9) classification report 14540-09 from SNPE-France/04-2009
(10) classification report 1226105 from SNPE-France/05-2005
(11) classification reports 11625-04 & 12261-05 from SME/SNPE-France/03-2004 & 05-2005
(12) test report 11624-04 from SNPE-France/03-2004
(13) test report 05-0530 from Fire Test Laboratory Airbus Deutschland GmbH – 2005
(14) test report P60-08-0018 (test according to DIN 54837, classification according to DIN 5510-2) from RST-Germany/01-2008
(15) test report P60-08-3107 (test according to EN ISO 5659, evaluation according to DIN 5510-2) from RST-Germany/02-2008.