Product Guide Issue 03 | Page 8

S E R V O T O U G H LaserSP 2930 HIGH-SENSITIVITY CROSS-STACK TDL ANALYZER FEATURES AND BENEFITS A high-performance gas analyzer designed for continuous in-situ monitoring, the LaserSP 2930 delivers a fast response time and highly stable performance. Suitable for measuring a range of gases including HCl, HF, H 2 O, H 2 S, HCN, and other hydrocarbons, the LaserSP is ideal for a wide range of process, combustion control and emissions applications. Designed for Zone 1 and Zone 2 hazard rated (gas/dust) locations In-situ with no sample conditioning delivers reliable operation HAZARDOUS AREA GAS MEASURES MULTIPLE % PERCENT ppm Wavelength Modulated Spectroscopy provides wide dynamic range and lowest cross-interference TRACE APPLICATIONS The DF-140E allows for reliable oxygen measurement in a wide variety of environments, including outdoors and in explosive environments with a NEMA 7 remote sensor enclosure. Using the revolutionary non-depleting E-Sensor, the DF-140E delivers reliable readings without frequent recalibration and periodic sensor replacement. FEATURES AND BENEFITS ATEX, IECEx and North American hazardous area approvals. ATEX Cat 3 (Gases) and Cat 2 (Dusts) IECEx Zone 2 and Zone 21. CSA Divisions and Zones (gas and dust) HAZARDOUS AREA GAS MEASURES MULTIPLE % APPLICATION PERCENT ppm TRACE APPLICATIONS Advanced multipass cell delivers ppb or low ppm detection limits Innovative PeakLock pattern recognition line tracking eliminates drift over extended operational periods APPLICATIONS Refinery monitoring: H 2 S and CO 2 (during natural gas refinement) HF and HCI impurity monitoring in process gas Monitoring H 2 S during biogas production H 2 O and H 2 S in natural gas P8 ENSURE A FULL LIFETIME OF PERFORMANCE TRACE PROCESS CONTROL OXYGEN QUALITY PROCESS CONTROL S E R V O T O U G H DF-320E HIGH-RELIABILITY TRACE AND PERCENT O 2 MEASUREMENTS IN HAZARDOUS AREA LOCATIONS Designed for use in harsh and hazardous areas, the DF-320E uses Servomex’s unique, non-depleting Coulometric sensor technology to give highly stable O 2 measurements, making it ideal for applications including hydrogen, propene and polyethylene production, oil refining and petrochemical process monitoring. HAZARDOUS AREA FEATURES AND BENEFITS GAS MEASURES Microprocessor-driven for easy configuration and maintenance O 2 ULTRA TRACE Coulometric sensor delivers accurate results with no sensor drifting, false low readings, or frequent calibration requirements OXYGEN For use in Class 1/Div 2 APPLICATION ppb ppm PROCESS CONTROL TRACE APPLICATIONS Hydrogen production QUALITY Polypropylene production Polyethylene production Oil refining SENSING TECHNOLOGY S E R V O T O U G H LaserExact 2950 ppm SENSING TECHNOLOGY QUALITY Natural gas contaminants – H 2 O, CO 2 , H 2 S Specifically designed for extractive trace analysis applications, the LaserExact 2950’s TDL technology offers unsurpassed low ppb detection limits for most gases, making it ideal for the measurement of trace gases offline. APPLICATION Reactor process control Moisture in VCM Zone 2/Div 2 hazard-rated locations and use without purge MEASURES APPLICATIONS Chemical reactor – inert gas control O 2 SENSING TECHNOLOGY In-situ with low purge gas consumption FEATURES AND BENEFITS STAB-EL option allows for accurate measurement in the presence of acid gases GAS Blanketing and inerting Line width correction delivers accurate measurement with variations in matrix EXTRACTIVE TDL TRACE MULTI-GAS ANALYZER, DESIGNED FOR MEASURING TRACE GASES OFFLINE Long-term reliability and stability with minimal maintenance Durability – can be used in Class 1, Div 1 or 2 areas Combustion control systems for process heaters and crackers S E R V O T O U G H LaserCompact 2940 Optimized for measurement across pipes and along short measurement cells and able to measure through very thin nozzles, reducing or even eliminating consumption of purge gas, the LaserCompact 2940 delivers the fast response time, highly stable performance and minimum sample conditioning advantages of TDL technology. FEATURES AND BENEFITS Pressure swing absorber nitrogen skids Ammonia slip control in DeNOx plants SHORT PATH LENGTH TDL ANALYZER PROCESS CONTROL HAZARDOUS AREA RELIABLE RESULTS IN A TESTING RANGE OF ENVIRONMENTS EMISSIONS Emission control systems for CEMS APPLICATION S E R V O T O U G H DF-140E HAZARDOUS AREA GAS MEASURES APPLICATION ppb MULTIPLE ULTRA TRACE ppm TRACE PROCESS CONTROL QUALITY SENSING TECHNOLOGY Petrochemical applications S E R V O T O U G H DF-340E HIGH-SENSITIVITY TRACE/ PERCENT COULOMETRIC O 2 ANALYZER CERTIFIED FOR HAZARDOUS AREA USE Designed for heated or external locations, the DF-340E remains stable in changing sample and flow rate conditions, and is designed to provide measurements of trace or percent level O 2 in pure gas streams and multi-gas backgrounds. It is ideal for upset-prone conditions. HAZARDOUS AREA FEATURES AND BENEFITS ATEX II and IECEx Certified Class 1/Div 2 Groups A,B,C and D certified Suitable for outdoor installation, with NEMA 4-rated sensor enclosure options GAS MEASURES O 2 ULTRA TRACE OXYGEN APPLICATION ppb ppm TRACE PROCESS CONTROL Multiple background gas stream monitoring, with simplified ongoing maintenance requirements QUALITY APPLICATIONS Pressure swing absorber N 2 skids Reactor process control SENSING TECHNOLOGY Blanketing and inerting SENSING TECHNOLOGY Oil refinery monitoring Petrochemical process monitoring Visit servomex.expert/service P9 or contact your local business center today