SERVOTOUGH Oxy 1800
SAFE AREA
ACCURATE AND STABLE
SAFE AREA O 2 ANALYZER
Designed to reliably measure up to 100% O2 in
many industrial applications, the Oxy 1800 is a
stable, accurate and highly specific O2 analyzer
for safe area use.
FEATURES AND BENEFITS
Internal/external use (IP66/NEMA 4X rated)
Special version for solvent-bearing samples
mA range and alarm outputs aids integration
into control systems
Easy to set-up, install and operate
APPLICATIONS
Waste water treatment
Food storage
Marine inerting applications
Inert blanketing
GAS MEASURES APPLICATION
OXYGEN
PERCENT
SENSING TECHNOLOGY
PROCESS
CONTROL
SAFETY
SERVOTOUGH Oxy 1900
HAZARDOUS AREA
PARAMAGNETIC DIGITAL O 2
ANALYZER DESIGNED FOR
HAZARDOUS AREA USE
Offering industry-standard features alongside
revolutionary, value-added options, the
Oxy 1900 O2 gas analyzer sets new standards
of flexibility, stability and reliability from a
single, cost-effective unit.
FEATURES AND BENEFITS
Safe Area to Zone 1/Division 1
hazard-rated locations
Heated sample gas compartment provides
improved measurement performance with
optional sample heater for simplified sample
conditioning system design
Unique Servomex Flowcube flow sensor
technology for improved safety
Internal pressure compensation option available
for improved measurement performance
Modbus communications available as standard
SIL 2 hardware compliant
APPLICATIONS
Process control
Safety-critical oxidation, such as ethylene
oxide and propylene oxide purity
Flare stack analysis
Vapor recovery
GAS MEASURES APPLICATION
OXYGEN
PERCENT
PROCESS
CONTROL
SAFETY
SENSING TECHNOLOGY
SERVOTOUGH OxyExact 2200
HAZARDOUS AREA
HIGH-SPEC PROCESS O 2
ANALYZER OFFERS SAFE OR
HAZARDOUS AREA CONTROL
WITH UP TO SIX TRANSMITTERS
The OxyExact 2200 high-specification O2
analyzer offers an unrivaled combination of
precision, flexibility and performance for optimum
process and safety control. The OxyExact 2200
can be configured with a safe or hazardous
area control unit with up to six transmitters.
FEATURES AND BENEFITS
Zone 1 certified to ATEX Cat 2, IECEx, TIIS and
FM/CSA Class 1 Division 1
Up to six transmitters can be connected to
one control unit
Control units use an option card based I/O
system to allow expansion of I/O to suit
system requirements
Three enclosure systems allow sampling of
any flammable gas up to 100% O2 and
pressures of up to 45psia
High-temperature transmitter eliminates need
to condense hot wet samples prior to analysis
SIL 2 hardware compliant
APPLICATIONS
Oxidation control reactions
EO, PTA and EDC manufacturing
Catalyst regeneration
Solvent recovery
GAS MEASURES APPLICATION
OXYGEN
PERCENT
PROCESS
CONTROL
SAFETY
SENSING TECHNOLOGY
P05