Product Guide 2020 | Page 18

SERVOPRO FID
SERVOPRO Chroma
SERVOPRO Plasma

SERVOPRO FID

SAFE AREA
TRACE HYDROCARBON ANALYZER IDEAL FOR AIR SEPARATION UNITS( ASU) SAFETY AND QUALITY CONTROL APPLICATIONS
A Flame Ionization Detector( FID) analyzer designed to assure safe operation for cryogenic ASU, the FID ensures the level of Total Hydrocarbons( THC) is maintained below flammable limits, as well as providing quality control in pure O2, N2, Ar, air, He and CO2.
FEATURES AND BENEFITS
Electrical safety to IEC 61010-1. In compliance with Low Voltage, EMC and applicable Directives
Excellent output resolution over three operating ranges
Electronic flow controllers for air, fuel and sample for no dependency to atmospheric pressure variations and inlet pressure variation
APPLICATIONS
Cryogenic air separation Process control Food gas manufacture Product validation
GAS MEASURES APPLICATION
TOTAL HYDROCARBONS
FLAME IONIZATION DETECTOR
TRACE PPM
SENSING TECHNOLOGY
SAFETY
QUALITY

SERVOPRO Chroma

SAFE AREA
HIGHLY VERSATILE TRACE GAS ANALYZER PLATFORM CONFIGURABLE TO A WIDE RANGE OF APPLICATIONS
FEATURES AND BENEFITS
Fully automated – tune to the application – system for unique simplicity of use
Standalone system requires no third-party software or computer to operate
For CH4 / NMHC measurements, the Plasma HC system requires no FID and therefore no H2 fuel gas
GAS MEASURES APPLICATION
MULTIPLE PERCENT
Offering a non-depleting Plasma Emission
Detector( PED), Flame Ionization Detector( FID) and Thermal Conductivity Detector( TCD), the
TRACE PPM
Chroma analyzer is one of the most versatile gas
analyzers for trace gas measurement available.
ULTRA TRACE
Most applications will be satisfied by a single 4U rack analyzer configuration, making the Chroma a compact, cost-effective solution for continuous process control or quality monitoring.
APPLICATIONS
Medical gas production
Air separation plants Cryogenic truck loading station High purity gas production
PPB
SENSING TECHNOLOGY
PROCESS CONTROL
QUALITY
FLAME IONIZATION DETECTOR

SERVOPRO Plasma

SAFE AREA
RELIABLE MONITORING OF N 2 IN Ar AND He, OPTIMIZED FOR AIR SEPARATION UNIT( ASU) PLANT OPERATIONS
Specifically designed for the continuous monitoring of N2 in Ar or He or both, the Plasma’ s non-depleting Plasma Emission Detector provides an accurate, highly stable and reliable measurement ideal for the requirements of ASU plant operators.
FEATURES AND BENEFITS
Electrical safety to IEC 61010-1: Ed 3. In compliance with Low Voltage, EMC and applicable Directives
Wide measurement range – 0-1ppm, 0-10ppm, 0-100ppm( higher on request)
Electronic flow control system for low flow consumption and reading stability
APPLICATIONS
Argon production Truck loading Pure gas bottling Specialty gas laboratories
GAS MEASURES APPLICATION
NITROGEN TRACE PPM QUALITY
SENSING TECHNOLOGY
P10