PowerSync Catalogue 2018 | Page 16

Quadralux Q2 Spotlight LS9120 Network Topology - PowerSync™ Dimmable PowerSync™ Topology 1 - Single Trunk Cable 150m (492') max Control Signal 120-277V 50/60Hz T LS6540 PowerSync™ Data Injector I PowerSync™ Topology 2 - Split Trunk Cable Combined length of both trunk cables can not exceed 150m (492'). Loop to next PowerSync™ Data Injector 10m (33') max T 120-277V 50/60Hz LS6540 PowerSync™ Data Injector I T Up to 45 luminaires per run under the following conditions: ͠ ͠ Max total cable run length 150m (492') in up to two trunk cables T Terminator Use PowerSync™ terminator, supplied with leader cable to terminate last luminaire in chain. ͠ ͠ Refer to 'Maximum Circuit Load' table for circuit limitations ͠ ͠ Always observe local electrical codes for branch circuit current limitations ͠ ͠ For run length in excess of 30m (100') use a wire size not lower than 14 AWG I Maximum Current Through cables and connectors, using Lumascape supplied jumper and leader cables ≤16.0A. Maximum Circuit Load Connection Type Maximum Number of Interconnected Fixtures Voltage 12.8A 16A 120V 41 45 240V 45 45 277V 45 45 Circuits can be configured as either connectorised or hardwired. For details consult installation instructions and comply with local electrical codes. Refer to PowerSync™ installation manual for maximum distance information and typology options. For non-continuous runs contact factory for details. NOTE: The above diagrams are intended to show electrical pathways between luminaires and ancillary device. These diagrams are not intended to show type or colour of cord / wire, luminaire input voltage rating, wire gauge or approved use of the cord / wire supplied with luminaires. 16