Table 6 — Hilti Carbon Steel and Stainless Steel KB-TZ2 design strength with masonry failure modes in the top of uncracked fully grouted CMU walls and installed at minimum edge distance parallel with masonry course 1 , 2 , 3 , 4 , 5
Nominal anchor diameter in .
3 / 8
1 / 2
5 / 8
Effective embedment in . ( mm ) f ́m = 1500 psi ( 10.3 MPa ) lb ( kN )
Tension ( lesser of breakout or pullout ) - ФN n
f ́m = 2000 psi ( 13.8 MPa ) lb ( kN ) f ́m = 2500 psi ( 17.2 MPa ) lb ( kN ) f ́m = 3000 psi ( 20.7 MPa ) lb ( kN )
Shear ( lesser of breakout , pryout , or crushing ) - ФV n
f ́m = 1500 psi ( 10.3 MPa ) lb ( kN ) f ́m = 2000 psi ( 13.8 MPa ) lb ( kN ) f ́m = 2500 psi ( 17.2 MPa ) lb ( kN ) f ́m = 3000 psi ( 20.7 MPa ) lb ( kN )
1-1 / 2
610
610
610
610
700
810
905
995
( 38 )
( 2.7 )
( 2.7 )
( 2.7 )
( 2.7 )
( 3.1 )
( 3.6 )
( 4.0 )
( 4.4 )
2-1 / 2
1,040
1,120
1,120
1,120
1,100
1,270
1,420
1,555
( 64 )
( 4.6 )
( 5.0 )
( 5.0 )
( 5.0 )
( 4.9 )
( 5.6 )
( 6.3 )
( 6.9 )
2
590
590
590
590
905
1,045
1,165
1,275
( 51 )
( 2.6 )
( 2.6 )
( 2.6 )
( 2.6 )
( 4.0 )
( 4.6 )
( 5.2 )
( 5.7 )
3-1 / 4
1,040
1,040
1,040
1,040
1,265
1,460
1,635
1,790
( 83 )
( 4.6 )
( 4.6 )
( 4.6 )
( 4.6 )
( 5.6 )
( 6.5 )
( 7.3 )
( 8.0 )
2-3 / 4
1,430
1,430
1,430
1,430
2,575
2,975
3,325
3,645
( 70 )
( 6.4 )
( 6.4 )
( 6.4 )
( 6.4 )
( 11.5 )
( 13.2 )
( 14.8 )
( 16.2 )
4
1,585
1,585
1,585
1,585
2,775
3,205
3,585
3,925
( 102 )
( 7.1 )
( 7.1 )
( 7.1 )
( 7.1 )
( 12.3 )
( 14.3 )
( 15.9 )
( 17.5 )
1 Linear interpolation between embedment depths and masonry compressive strengths is not permitted .
2 Tabular values are for a single anchor located at minimum edge of 1-3 / 4-in ( 2-3 / 4-in for 5 / 8-in diameter ) from edge parallel with masonry course with no additional influence from nearby edges or additional anchors . For designs with the additional influence of nearby edges , a different edge distance , or additional anchors , use Hilti PROFIS Engineering Design software or perform anchor calculation using design equations from AC01 . 3 Compare masonry tabular values to the steel values in Table 8 . The lesser of the values is to be used for the design . 4 Tabular values are for static loads only . Seismic design is not permitted for uncracked masonry . 5 Tabular shear values are for shear force parallel to the edge parallel with the masonry course . For shear force perpendicular to the edge parallel with the masonry course , multiply design strength values in shear by the following reduction factors : 3 / 8-in and 1 / 2-in . diameter = 0.50 5 / 8-in diameter = 0.46
Table 7 — Hilti Carbon Steel and Stainless Steel KB-TZ2 design strength with masonry failure modes in the top of cracked fully grouted CMU walls and installed at minimum edge distance parallel with masonry course 1 , 2 , 3 , 4 . 5
Nominal anchor diameter in .
3 / 8
1 / 2
5 / 8
Effective embedment in . ( mm ) f ́c = 1500 psi ( 10.3 MPa ) lb ( kN )
Tension ( lesser of breakout or pullout ) - ФN n
f ́c = 2000 psi ( 13.8 MPa ) lb ( kN ) f ́c = 2500 psi ( 17.2 MPa ) lb ( kN ) f ́c = 3000 psi ( 20.7 MPa ) lb ( kN )
Shear ( lesser of breakout , pryout , or crushing ) - ФV n
f ́c = 1500 psi ( 10.3 MPa ) lb ( kN ) f ́c = 2000 psi ( 13.8 MPa ) lb ( kN ) f ́c = 2500 psi ( 17.2 MPa ) lb ( kN ) f ́c = 3000 psi ( 20.7 MPa ) lb ( kN )
1-1 / 2
440
440
440
440
495
575
640
700
( 38 )
( 2.0 )
( 2.0 )
( 2.0 )
( 2.0 )
( 2.2 )
( 2.6 )
( 2.8 )
( 3.1 )
2-1 / 2
735
810
810
810
785
910
1,015
1,110
( 64 )
( 3.3 )
( 3.6 )
( 3.6 )
( 3.6 )
( 3.5 )
( 4.0 )
( 4.5 )
( 4.9 )
2
500
560
560
560
635
735
825
900
( 51 )
( 2.2 )
( 2.5 )
( 2.5 )
( 2.5 )
( 2.8 )
( 3.3 )
( 3.7 )
( 4.0 )
3-1 / 4
820
950
985
985
905
1,045
1,165
1,280
( 83 )
( 3.6 )
( 4.2 )
( 4.4 )
( 4.4 )
( 4.0 )
( 4.6 )
( 5.2 )
( 5.7 )
298
860
860
860
860
1,840
2,125
2,375
2,605
( 70 )
( 3.8 )
( 3.8 )
( 3.8 )
( 3.8 )
( 8.2 )
( 9.5 )
( 10.6 )
( 11.6 )
4
950
950
950
950
1,985
2,290
2,560
2,805
( 102 )
( 4.2 )
( 4.2 )
( 4.2 )
( 4.2 )
( 8.8 )
( 10.2 )
( 11.4 )
( 12.5 )
1 Linear interpolation between embedment depths and masonry compressive strengths is not permitted .
2 Tabular values are for a single anchor located at minimum edge of 1-3 / 4-in ( 2-3 / 4-in for 5 / 8-in diameter ) from edge parallel with masonry course with no additional influence from nearby edges or additional anchors . For designs with the additional influence of nearby edges , a different edge distance , or additional anchors , use Hilti PROFIS Engineering Design software or perform anchor calculation using design equations from AC01 . 3 Compare masonry tabular values to the steel values in Table 8 . The lesser of the values is to be used for the design . 4 Tabular values are for static loads only . For seismic loads , multiply design strength values in tension and shear by the following reduction factors : 3 / 8-in diameter = 0.75 1 / 2-in diameter = 0.68 5 / 8-in diameter = 0.66
5 Tabular shear values are for shear force parallel to the edge parallel with the masonry course . For shear force perpendicular to the edge parallel with the masonry course , multiply design strength values in shear by the following reduction factors : 3 / 8-in and 1 / 2-in . diameter = 0.50 5 / 8-in diameter = 0.46
68 Masonry Fastening Technical Guide Edition 24 | 7.4 KWIK BOLT TZ2 EXPANSION ANCHOR Hilti , Inc . 1-800-879-8000 | en español 1-800-879-5000 | www . hilti . com | Hilti ( Canada ) Corporation | www . hilti . ca | 1-800-363-4458