Table 7 — Hilti HIT-HY 270 adhesive design strength with masonry / bond failure for threaded rod in the top of cracked fully grouted CMU walls and installed at minimum edge distance parallel with masonry course 1 , 2 , 3 , 4 , 5 , 6 , 7 , 8
Nominal anchor diameter in .
1 / 2
5 / 8
3 / 4
Effective embedment in . ( mm ) f ́m = 1500 psi ( 10.3 MPa ) lb ( kN )
Tension ( lesser of breakout or bond ) — ΦN n
f ́m = 2000 psi ( 13.8 MPa ) lb ( kN ) f ́m = 2500 psi ( 17.2 MPa ) lb ( kN ) f ́m = 3000 psi ( 20.7 MPa ) lb ( kN )
Shear ( lesser of breakout , pryout , or crushing ) — ΦV n
f ́m = 1500 psi ( 10.3 MPa ) lb ( kN ) f ́m = 2000 psi ( 13.8 MPa ) lb ( kN ) f ́m = 2500 psi ( 17.2 MPa ) lb ( kN ) f ́m = 3000 psi ( 20.7 MPa ) lb ( kN )
2-3 / 4
280
280
280
280
710
710
710
710
( 70 )
( 1.2 )
( 1.2 )
( 1.2 )
( 1.2 )
( 3.2 )
( 3.2 )
( 3.2 )
( 3.2 )
4-1 / 2
455
455
455
455
940
1,085
1,160
1,160
( 114 )
( 2.0 )
( 2.0 )
( 2.0 )
( 2.0 )
( 4.2 )
( 4.8 )
( 5.2 )
( 5.2 )
6-3 / 4
685
685
685
685
940
1,085
1,215
1,330
( 171 )
( 3.0 )
( 3.0 )
( 3.0 )
( 3.0 )
( 4.2 )
( 4.8 )
( 5.4 )
( 5.9 )
10
1,015
1,015
1,015
1,015
940
1,085
1,215
1,330
( 254 )
( 4.5 )
( 4.5 )
( 4.5 )
( 4.5 )
( 4.2 )
( 4.8 )
( 5.4 )
( 5.9 )
3-1 / 8
275
275
275
275
705
705
705
705
( 79 )
( 1.2 )
( 1.2 )
( 1.2 )
( 1.2 )
( 3.1 )
( 3.1 )
( 3.1 )
( 3.1 )
4-1 / 2
400
400
400
400
1,015
1,015
1,015
1,015
( 114 )
( 1.8 )
( 1.8 )
( 1.8 )
( 1.8 )
( 4.5 )
( 4.5 )
( 4.5 )
( 4.5 )
6-3 / 4
600
600
600
600
1,055
1,215
1,360
1,490
( 171 )
( 2.7 )
( 2.7 )
( 2.7 )
( 2.7 )
( 4.7 )
( 5.4 )
( 6.0 )
( 6.6 )
10
890
890
890
890
1,055
1,215
1,360
1,490
( 254 )
( 4.0 )
( 4.0 )
( 4.0 )
( 4.0 )
( 4.7 )
( 5.4 )
( 6.0 )
( 6.6 )
3-1 / 2
585
585
585
585
1,490
1,490
1,490
1,490
( 89 )
( 2.6 )
( 2.6 )
( 2.6 )
( 2.6 )
( 6.6 )
( 6.6 )
( 6.6 )
( 6.6 )
4-1 / 2
755
755
755
755
1,915
1,915
1,915
1,915
( 114 )
( 3.4 )
( 3.4 )
( 3.4 )
( 3.4 )
( 8.5 )
( 8.5 )
( 8.5 )
( 8.5 )
6-3 / 4
1,130
1,130
1,130
1,130
2,225
2,570
2,875
2,875
( 171 )
( 5.0 )
( 5.0 )
( 5.0 )
( 5.0 )
( 9.9 )
( 11.4 )
( 12.8 )
( 12.8 )
10
1,675
1,675
1,675
1,675
2,225
2,570
2,875
3,145
( 254 )
( 7.5 )
( 7.5 )
( 7.5 )
( 7.5 )
( 9.9 )
( 11.4 )
( 12.8 )
( 14.0 )
1 Linear interpolation between embedment depths and masonry compressive strengths is not permitted . 2 Tabular values are for a single anchor located at minimum edge of 1-3 / 4-in ( 2-3 / 4-in for 3 / 4-in diameter ) from edge parallel with masonry course with no additional influence from nearby edges or additional anchors . For designs with the additional influence of nearby edges , a different edge distance , or additional anchors , use Hilti PROFIS Engineering Design software or perform anchor calculation using design equations from AC58 . 3 Compare masonry tabular values to the steel values in the Appendix . The lesser of the values is to be used for the design . 4 Data is for Temperature Range A : Maximum short term temperature = 130 ° F ( 55 ° C ) | Maximum long term temperature = 110 ° F ( 43 ° C ).
For Temperature Range B : Maximum short term temperature = 176 ° F ( 80 ° C ) | Maximum long term temperature = 110 ° F ( 43 ° C ), multiply design strength values by 0.91 . 5 Tabular values are for dry masonry conditions . For water saturated masonry conditions , multiply design strength values by : α sa t , 1 / 2-in diameter - α sat
= 1.00 5 / 8-in and 3 / 4-in diameter - α sat
= 0.93
6 Tabular values are for static loads only . For seismic loads , multiply design strength values in tension and shear by the following reduction factors : 1 / 2-in diameter = 0.65 5 / 8-in diameter = 0.66 3 / 4-in diameter = 0.74
7 Tabular shear values are for shear force parallel to the edge parallel with the masonry course . For shear force perpendicular to the edge parallel with the masonry course , multiply design strength values in shear by the following reduction factors : 1 / 2-in and 5 / 8-in . diameter = 0.50 3 / 4-in diameter = 0.46
8 Tabular values are for short term loads only . For sustained loads including overhead use , see Section 3.0 and multiply design strength values in tension and shear by 0.80 .
40 Masonry Fastening Technical Guide Edition 24 | 7.1 HIT-HY 270 HYBRID FOR MASONRY CONSTRUCTION Hilti , Inc . 1-800-879-8000 | en español 1-800-879-5000 | www . hilti . com | Hilti ( Canada ) Corporation | www . hilti . ca | 1-800-363-4458