Plumbing Africa May 2017 | Page 62

3 SANS 10252-Part 1 and SANS 10254 4 SANS 10252-Part 1 and SANS 10254 SANS 10252-Part 1 and SANS 10254 REPAIRS/MAINTENANCE OF AN EXPANSION CONTROL VALVE The following c areas of compliance in terms of the SANS requirements must be undertaken when the repairs/maintenance of an Expansion Control Valve is undertaken. Repair/Maintenance shall include the replacement of an Expansion Control Valve and or installation of an Expansion Control Valve to an existing installation. COMPONENTS (INCL. PIPES, FITTINGS AND FIXTURES) 1. All materials, pipes, fittings, components and fixtures used in the repair/maintenance must meet SANS 10252 – 1 section 5 (when applicable the supplier must be able to provide proof that the component complies to the relevant SANS standard) and must be listed on the JASWIC acceptance list. 2. Materials, pipes, fittings, components and fixtures must be installed as per regulation and manufacturers guidelines. 3. Connections to all components must be union type for ease of replacement. 4. Adequate access must be provided to remove or maintain or replace any component. EXPANSION CONTROL VALVE 1. The Expansion Control Valve shall have the same pressure rating as other valves used in the system. 2. The pressure rating of the Expansion Control Valve maybe less than the rated pressure of the storage water heater but shall never exceed it. 3. An isolating valve, gate valve, non-return valve or any other flow control device shall not be provided between an Expansion Control Valve and the water 4. The discharge pipes from Expansion Control valve shall a) never be joined together with other discharge pipes, b) led to a discharge point which is visible outside the building and in a position where the discharge from the pipe will not cause a nuisance and cannot become blocked, c) installed in a manner that will obviate the development of water traps which could prevent the free return of air into the system, d) sized not less than the size of the outlet of the valve for which the pipe is intended, and PLUMBING CERTIFICATE OF COMPLIANCE 1. A plumbing certificate of compliance from the Plumbing Industry Registration Board (PIRB) the SAQA registered professional body for plumbers, shall be issued for the installation, replacement or repair of any plumbing works carried out on the hot water reticulation system. WRITTEN NOTICE OF NON-COMPLIANCE When any replacement, repair or maintenance work is being done on any components in the system, a written notice of all non-compliances must be given by the plumber to the owner or occupant for the owner’s attention. See annex A. REPAIRS/MAINTENANCE OF A PRESSURE CONTROL VALVE 1. The following critical areas of compliance in terms of the SANS requirements must be undertaken when the repairs/maintenance of a Pressure Control Valve is undertaken. Repair/Maintenance shall include the replacement of a Pressure Control Valve and or installation of a Pressure Control Valve to an existing installation. COMPONENTS (INCL. PIPES, FITTINGS AND FIXTURES) 1. All materials, pipes, fittings, components and fixtures used in the repair/maintenance must meet SANS 10252 – 1 section 5 (when applicable the supplier must be able to provide proof that the component complies to the relevant SANS standard) and must be listed on the JASWIC acceptance list. 2. Materials, pipes, fittings, components and fixtures must be installed as per regulation and manufacturers guidelines. 3. Connections to all components must be union type for ease of replacement. 4. Adequate access must be provided to remove or maintain or replace any component. PRESSURE CONTROL VALVE 1. The Pressure Control Valve shall have the same pressure rating as other valves used in the system. 2. The pressure rating of the Pressure Control Valve maybe less than the rated pressure of the storage water heater but shall never exceed it. 3. The location of the Pressure Control Valve must be related to the required downstream flow-pressures. 4. See requirements of the Expansion Control Valve if the Pressure Control Valve incorporates an Expansion Control Valve. PLUMBING CERTIFICATE OF COMPLIANCE 1. A plumbing certificate of compliance from the Plumbing Industry Registration Board (PIRB) the SAQA registered professional body for plumbers, shall be issued for the installation, replacement or repair of any plumbing works carried out on the hot water reticulation system. WRITTEN NOTICE OF NON-COMPLIANCE 1. When any replacement, repair or maintenance work is being done on any components in the system, a written notice of all non-compliances must be given by the plumber to the owner or occupant for the owner’s attention. See annex A. REPAIRS/MAINTENANCE OF A VACUUM CONTROL VALVES The following critical areas of compliance in terms of the SANS requirements must be undertaken when the repairs/maintenance of a Vacuum Control Valves is undertaken. Repair/Maintenance shall include the replacement of a Vacuum Control Valves and or installation of a Vacuum Control Valves to an existing installation. COMPONENTS (INCL. PIPES, FITTINGS AND FIXTURES) 1. All materials, pipes, fittings, components and fixtures used in the repair/maintenance must meet SANS 10252 – 1 section 5 (when applicable the supplier must be able to provide proof that the component complies to