2.0 PIPE SHOE MP-PS | |||||||
2.2 MP-PS 2-2 | |||||||
Table 11 : MP-PS 2-2 Allowable Strength Design ( ASD ) Load Data per MSS SP-58 1 , 2 , 3 ( continued ) |
Order designation |
+/ -Fx lb ( kN ) |
+/ -Fy lb ( kN ) |
+ Fz lb ( kN ) |
-Fz lb ( kN ) |
High MP-PS 2-2
MP-PS H2-2 21-26 1 / 2 " OC 1730 ( 7.7 ) 440 ( 1.96 ) 2750 ( 12.23 ) 2100 ( 9.34 )
MP-PS H2-2 26-31 3 / 4 " OC 1750 ( 7.78 ) 440 ( 1.96 ) 2750 ( 12.23 ) 2100 ( 9.34 )
MP-PS H2-2 32-37 1 " OC 1770 ( 7.87 ) 430 ( 1.91 ) 2750 ( 12.23 ) 2100 ( 9.34 )
|
FY |
FZ- |
Pipe Axis |
||||||||
MP-PS H2-2 38-44 1-1 / 4 " OC 1790 ( 7.96 ) 420 ( 1.87 ) 2750 ( 12.23 ) 2100 ( 9.34 ) |
|||||||||||
MP-PS H2-2 45-51 1-1 / 2 " OC 1800 ( 8.01 ) 420 ( 1.87 ) 2750 ( 12.23 ) 2100 ( 9.34 ) |
|||||||||||
MP-PS H2-2 52-58 OC 1820 ( 8.1 ) 410 ( 1.82 ) 2750 ( 12.23 ) 2100 ( 9.34 ) |
|||||||||||
MP-PS H2-2 59-65 2 " OC 1830 ( 8.14 ) 410 ( 1.82 ) 2750 ( 12.23 ) 2100 ( 9.34 )
MP-PS H2-2 68-74 OC 1860 ( 8.27 ) 400 ( 1.78 ) 2750 ( 12.23 ) 2100 ( 9.34 )
|
FX |
||||||||||
MP-PS H2-2 75-81 2-1 / 2 " OC 1870 ( 8.32 ) 390 ( 1.73 ) 2750 ( 12.23 ) 2100 ( 9.34 ) |
|||||||||||
MP-PS H2-2 88-94 3 " OC 1910 ( 8.5 ) 380 ( 1.69 ) 2750 ( 12.23 ) 2100 ( 9.34 ) |
|||||||||||
MPPS H2-2 100-108 3-1 / 2 " OC 1940 ( 8.63 ) 370 ( 1.65 ) 2750 ( 12.23 ) 2100 ( 9.34 ) |
|||||||||||
MP-PS H2-2 110-118 4 " OC 1940 ( 8.63 ) 360 ( 1.6 ) 2750 ( 12.23 ) 2100 ( 9.34 ) |
|||||||||||
MP-PS H2-2 125-133 OC 1940 ( 8.63 ) 360 ( 1.6 ) 2750 ( 12.23 ) 2100 ( 9.34 ) |
|||||||||||
MP-PS H2-2 136-144 5 " OC 1940 ( 8.63 ) 350 ( 1.56 ) 2750 ( 12.23 ) 2100 ( 9.34 )
MP-PS H2-2 152-162 OC 1940 ( 8.63 ) 330 ( 1.47 ) 2750 ( 12.23 ) 2100 ( 9.34 )
|
FZ + |
||||||||||
MP-PS H2-2 163-173 6 " OC 1940 ( 8.63 ) 330 ( 1.47 ) 2750 ( 12.23 ) 2100 ( 9.34 ) |
|||||||||||
MP-PS H2-2 192-202 7 " OC 1940 ( 8.63 ) 310 ( 1.38 ) 2750 ( 12.23 ) 2100 ( 9.34 ) |
|||||||||||
MP-PS H2-2 217-227 8 " OC 1940 ( 8.63 ) 300 ( 1.33 ) 2750 ( 12.23 ) 2100 ( 9.34 ) |
|||||||||||
MP-PS H2-2 244-254 OC 1940 ( 8.63 ) 290 ( 1.29 ) 2750 ( 12.23 ) 2100 ( 9.34 ) |
|||||||||||
MP-PS H2-2 267-277 10 " OC 1940 ( 8.63 ) 280 ( 1.25 ) 2750 ( 12.23 ) 2100 ( 9.34 ) |
|||||||||||
MP-PS H2-2 318-328 12 " OC 1940 ( 8.63 ) 260 ( 1.16 ) 2750 ( 12.23 ) 2100 ( 9.34 ) |
|||||||||||
1 Tabulated directional values apply separately in each direction . A combination of loads must be considered separately , and an appropriate interaction equation defined by the design professional must be applied . 2 MSS SP-58 values are based off the safety factors provided in the MSS SP-58 . 3 Tabulated values as shown does not include or account for anchorage . Anchorage must be determined separately and may reduce the overall capacity from the tabulated values . |
|||||||||||
2023 |
25 |