PECM Issue 57 2022 | Page 67

MACHINING & MACHINERY
DRILL SERVICE ( HORLEY ) LTD WWW . DRILL-SERVICE . CO . UK
Hand Tools P09 XEBEC Brush TM Surface End Type
CNC deburring and polishing P07 XEBEC Brush TM Surface
P10 XEBEC Brush TM Wheel Type
Cutter mark removal and flat surface polishing .
Deburring after face-milling , end-milling and drilling . Cutter mark removal and surface polishing .
Deburring after end-milling , threading , and drilling . Polishing side surface and inner diameter .
P18 XEBEC Stone TM Flexible Shaft P11 XEBEC Brush TM Crosshole
P15 XEBEC Back Burr Cutter and Path TM
Hole deburring .
Deburring after drilling . Cutter mark removal and inner diameter polishing .
Deburring after drilling .
FOR YOUR DEBURRING AND SURFACE FINISHING SOLUTION
Xebec deburring tools give an unrivalled performance versus traditional abrasive products , resulting in increased productivity , improved quality and reduced costs .
The UK ’ s most comprehensive stockist of these innovative tools .
TEL : 01293 774911 EMAIL : SALES @ DRILL-SERVICE . CO . UK Same day dispatch for all stock orders received before 3.45pm
Advanced Engineering Products and Services for the Manufacturing Industry Experts in Press Protection , Quality Assurance and Productivity
• Load Monitoring and Automation Systems for manufacturing equipment
• Process monitoring and control for assembly machines
• Manufacturing Execution Systems including downtime analysis
• Production recording systems
• Bespoke control systems
• Calibration services
• Repair / Maintenance
Measuring Immunoglobulin without Sample Degradation
ODIN is a new , compact , and reliable deep UV resonant Raman instrument developed by IS-Instruments ( IS-I ) and TOPTICA for measurement of biopharma products . ODIN is a new , compact , and reliable deep UV resonant Raman instrument developed by IS-Instruments ( ISI ) and TOPTICA for measurement of biopharma products . TOPTICA ’ s Industrial CW Laser TopWave 229 enables new Deep UV Raman Spectrometer ODIN .
The system combines the newly developed solid state diode laser TopWave 229 and a spatial heterodyne spectrometer integrated into a single instrument with a unique all-reflective backscatter Raman collection probe . Sample damage caused by extended laser exposure has been mitigated via the introductiwww . toptica . comon of a dynamic sample positioning stage .
www . toptica . com
Decade Monitoring Solutions Ltd Unit 3 , Octagon Business Centre , Miller St , Birmingham , B6 4NH Telephone : + 44 ( 0 ) 121 359 3978 E-mail : sales @ decade . co . uk www . decade . co . uk
Issue 57 PECM 67