MEASUREMENT & MONITORING
Temperature control for dyno testing of EV components
Electrical Vehicle bench tests demand wide temperature ranges and JULABO temperature control systems replicate coolant lines to provide precise simulation of real-life conditions .
A PRESTO A45 ( -45 ° C to 250 ° C ) with a flow meter / fluid bypass maintains temperature of the test bed while simultaneously regulating the flow rate of the fluid .
A typical testing requirement for the test bed is to hold 65 ° C with the component under different load conditions . At idle the PRESTO A45 can maintain 65 ° C with 30 % ( 1.8 kW ) power in a series of steps up to a full load test , the component requires cooling at 3-4 % ( 0.14 kW ) cooling input to remove heat generated .
www . julabo . com / en-gb
New pressure gauges MAN SC / LC - from Kobold
Introducing the latest version of the electronic digital pressure gauge ; MAN-SC for battery powered applications , and MAN- LC for 24Vdc power with IO-link .
• Alpha-numeric 14-segment reflective LCdisplay screen , full 5-digit display , and digit height of 16mm
• Electronic screen module with 90 ° incremental rotation ; for side mounted or inverted installations
• Adjustable gauge head position
• Capacitive touchpads access
• kPa , MPa , bar , mbar , psi , kN , N , torr , inWC , mmWC , inHg , USR Measuring units
• Password protected peak memory , and reset function
• 9V Lithium battery with 22,500 hours ( 2.5 years ).
• A zero ( tare ) for calibration
• Optional rubber protective case cover
• Measuring ranges from -1 … 0 ...+ 1600 Bar
www . koboldnews . co . uk
CTL Continuously Tunable Laser family : Measurements at the quantum limit
Lasers of TOPTICA ’ s CTL product family are made to be ideal tools for exciting microcavities or quantum dots , for pumping micro combs , as well as for component testing and spectroscopy . Their most important property is providing wide and continuous tunability without any modehops . They have high power , a narrow linewidth and low drift . Scans can be performed with highest resolution . This unique combination of features makes them outstanding in their field and enables researchers to perform measurements at the quantum limit .
The latest addition to this family is called CTL 900 . It is tunable between 880nm and 950nm . The long-awaited wavelength range is especially useful for resonantly exciting quantum dots , for spectroscopy or addressing e . g . rare earth ions or the Caesium D1 line .