PECM Issue 26 2017 | Page 58

HOW TO CHECK IF COOLING OUTPUT INSIDE ENCLOSURES IS SUFFICIENT By Jason Swann, Rittal Product Manager for Climate Manufacturing automation systems are delicate and very expensive pieces of kit, which perform vital functions for the businesses they serve. The enclosures that protect them must have strictly controlled internal environments with interior temperatures that are carefully maintained within a few degrees. If not, the impact can be harmful to the inverter drives, power supplies, contactors, PLCs and other electrical and electronic components operating within them. This requires careful control of the climate within the enclosure. Here, we offer some practical tips on how to evaluate an existing enclosure climate control through a series of simple checks. ike all electrical equipment, drives create heat and they therefore have a major influence on the temperatures inside enclosures. Drives are often quoted as having efficiency of 97 per cent, so one with a rated output of 150kW can produce as much as 4.5kW of heat. of a cooling unit should be specified so that the average internal enclosure temperature of 35°C can be guaranteed under all load conditions and under all the ambient conditions that could be met at the machine’s location. As well as the heat loss inside the enclosure, ambient temperatures within a production facility will also have an impact on the temperatures that a drive is operating within. A typical enclosure climate control system is designed for an internal enclosure temperature of 35°C. This means that the performance The first check is to measure the temperature within the enclosure to assess its climate control capability. Temperature sensors should be placed in a position within the airflow of the enclosure, sensors should not be placed on or near direct airflow from high temperature components. Otherwise temperature readings can be found to be inaccurate. L Checking the enclosure temperature. The sensors should be left to monitor the temperature trend over a period of time. If the sensor records air temperatures of well over 35°C (set point) then the output of the cooling unit should either be considered insufficient or, alternatively, that there has been a malfunction of the cold air routing in the enclosure. This means that the cooling air cannot reach (or can only partially reach) the temperature- sensitive components. Checking the control behaviour of cooling devices Another easy way of checking an enclosure climate control system is to observe the Climate control from the smallest to the largest. ENCLOSURES POWER DISTRIBUTION CLIMATE CONTROL