Description |
Environmental Conditions |
MT-B-O4 |
Dry indoor conditions( C1)
Indoor with temporary condensation( C2)
|
MT-B-O4 OC |
Outdoor, low to moderate pollution( C3 / C4- low) |
Ordering Information | |||
Description |
Weight Per
Piece, lbs( kg)
|
Quantity
Piece( s)
|
Item No. |
MT-B-O4 |
7.28( 3.3) |
4 |
2272098 |
Fx lb( kN) |
Fy lb( kN) |
Fz lb( kN) |
My lb ft( kN m) |
Mz lb ft( kN m) |
3,035( 13.50) |
700( 3.12) |
3,590( 15.98) |
3,810( 5.17) |
2,010( 2.73) |
1 Minimum safety factor, Ω, for tabulated values is 2.0. | ||||
2 Multiply tabulated values by 1.5 to obtain minimum Load and Resistance Factor Design | ||||
( LRFD) values. | ||||
3 See Figure 18. | ||||
4 Load values are for base connector only. The design professional is responsible for | ||||
checking concrete and fastener strength. | ||||
Fx lb( kN) |
Fy lb( kN) |
Fz lb( kN) |
My lb ft( kN m) |
Mz lb ft( kN m) |
4,095( 18.23) |
945( 4.21) |
4,665( 20.77) |
5,015( 6.80) |
2,645( 3.59) |
1 Maximum resistance factor, φ, for tabulated values is 0.75. | ||||
2 See Figure 18. | ||||
3 Load values are for base connector only. The design professional is responsible for | ||||
checking concrete and fastener strength. | ||||