Ordering Information | |||
Description |
Weight Per
Piece, lbs( kg)
|
Quantity
Piece( s)
|
Item No. |
MT-CC-30 |
0.60( 0.27) |
10 |
2322427 |
Fx lb( kN) |
Fy lb( kN) |
Fz lb( kN) |
1,010( 4.50) |
1,685( 7.50) |
1,120( 5.00) |
1 Minimum safety factor, Ω, for tabulated values is 2.6. | ||
2 Multiply tabulated values by 1.5 to obtain minimum Load and Resistance | ||
Factor Design( LRFD) values. | ||
3 See Figure 119. | ||
4 Loading in the negative Z-direction is not recommended for this connector. | ||
A. |
MT-30 |
B. |
MT-30 / 50 / 60 |
Figure 120 – Channel to-Girder Connection | |
A. |
MT-30 |
B. |
MT-70 / 80 / 90 / 100 |
Fx lb( kN) |
Fy lb( kN) |
Fz lb( kN) |
1,405( 6.26) |
2,345( 10.44) |
1,560( 6.96) |
1 Maximum resistance factor, φ, for tabulated values is 0.55. | ||
2 See Figure 119. | ||
3 Loading in the negative Z-direction is not recommended for this connector. | ||
Fx lb( kN) |
Fy lb( kN) |
Fz lb( kN) |
1,010( 4.50) |
2,035( 9.06) |
1,645( 7.33) |
1 Minimum safety factor, Ω, for tabulated values is 2.35. | ||
2 Multiply tabulated values by 1.5 to obtain minimum Load and Resistance | ||
Factor Design( LRFD) values. | ||
3 See Figure 120. | ||
4 Loading in the negative Z-direction is not recommended for this connector. | ||
Fx lb( kN) |
Fy lb( kN) |
Fz lb( kN) |
1,405( 6.26) |
2,645( 11.78) |
2,140( 9.53) |
1 Maximum resistance factor, φ, for tabulated values is 0.55. | ||
2 See Figure 120. | ||
3 Loading in the negative Z-direction is not recommended for this connector. | ||