A. |
MT-90 |
B. |
MT-B-GL EDB A |
C. |
MT-C-GL A |
D. |
MT-80( long side)/ 90 / 100 |
A. |
MT-100( long side) |
B. |
MT-B-GL EDB A |
C. |
MT-C-GL A |
D. |
MT-90 / 100 |
Fx lb( kN) |
Fy lb( kN) |
Fz lb( kN) |
Mx lb ft( kN m) |
My lb ft( kN m) |
Mz lb ft( kN m) |
995( 4.43) |
1.960( 8.72) |
6,095( 27.13) |
1,125( 1.53) |
1,780( 2.42) |
690( 0.94) |
1 Tabulated values are for elevator divider beam applications only. | |||||
2 Tabulated values must be used in conjunction with the stiffness values shown in Table 331. | |||||
3 Maximum resistance factor, φ, for tabulated values is 0.7. | |||||
4 Load values are for base connector only. The design professional is responsible for checking concrete | |||||
and fastener strength. Refer to the Modular Support Systems Technical Guide for MT-C-GL A | |||||
capacities. | |||||
5 See Figure 110. | |||||
Fx lb( kN) |
Fy lb( kN) |
Fz lb( kN) |
Mx lb ft( kN m) |
My lb ft( kN m) |
Mz lb ft( kN m) |
665( 2.96) |
1,100( 4.90) |
4,165( 18.53) |
720( 0.98) |
965( 1.31) |
470( 0.64) |
1 Tabulated values are for elevator divider beam applications only. | |||||
2 Tabulated values must be used in conjunction with the stiffness values shown in Table 331. | |||||
3 Minimum safety factor, Ω, for tabulated values is 2.1. | |||||
4 Multiply tabulated values by 1.5 to obtain minimum LRFD values. | |||||
5 Load values are for base connector only. The design professional is responsible for checking concrete | |||||
and fastener strength. Refer to the Modular Support Systems Technical Guide for MT-C-GL A | |||||
capacities. | |||||
6 See Figure 111. | |||||
Fx lb( kN) |
Fy lb( kN) |
Fz lb( kN) |
Mx lb ft( kN m) |
My lb ft( kN m) |
Mz lb ft( kN m) |
995( 4.43) |
1.655( 7.37) |
6,260( 27.85) |
1,080( 1.47) |
1,445( 1.96) |
705( 0.96) |
1 Tabulated values are for elevator divider beam applications only. | |||||
2 Tabulated values must be used in conjunction with the stiffness values shown in Table 331. | |||||
3 Maximum resistance factor, φ, for tabulated values, is 0.7. | |||||
4 Load values are for base connector only. The design professional is responsible for checking concrete | |||||
and fastener strength. Refer to the Modular Support Systems Technical Guide for MT-C-GL A | |||||
capacities. | |||||
5 See Figure 111. | |||||