Fx lb( kN) |
Fy lb( kN) |
Fz lb( kN) |
My lb ft( kN m) |
10,200( 45.38) |
1,745( 7.77) |
3,585( 15.95) |
1,865( 2.53) |
1 Tabulated values are for non-elevator applications only. | |||
2 Minimum safety factor, Ω, for tabulated values is 2.6. | |||
3 Multiply tabulated values by 1.5 to obtain Load and Resistance Factor Design | |||
( LRFD) values. | |||
4 Load values are for base connector only. Design professional is responsible for | |||
checking concrete and fastener strength. | |||
5 See Figure 99. | |||
Fx lb( kN) |
Fy lb( kN) |
Fz lb( kN) |
My lb ft( kN m) |
15,330( 68.20) |
2,625( 11.68) |
5,390( 23.98) |
2,425( 3.29) |
1 Tabulated values are for non-elevator applications only. | |||
2 Maximum resistance factor, φ, for tabulated values is 0.6. | |||
3 Load values are for base connector only. Design professional is responsible for | |||
checking concrete and fastener strength. | |||
4 See Figure 99. | |||
Fx lb( kN) |
Fy lb( kN) |
Fz lb( kN) |
330( 1.48) |
830( 3.70) |
4,145( 18.44) |
1 Tabulated values are for non-elevator applications only. | ||
2 Minimum safety factor, Ω, for tabulated values is 2.1. | ||
3 Multiply tabulated values by 1.5 to obtain minimum LRFD values. | ||
4 Load values are for base connector only. Design professional is responsible | ||
for checking concrete and fastener strength. | ||
5 See Figure 100. | ||
Fx lb( kN) |
Fy lb( kN) |
Fz lb( kN) |
495( 2.21) |
1,250( 5.57) |
5,235( 23.29) |
1 Tabulated values are for non-elevator applications only. | ||
2 Maximum resistance factor, φ, for tabulated values is 0.7. | ||
3 Load values are for base connector only. Design professional is responsible | ||
for checking concrete and fastener strength. | ||
4 See Figure 100. | ||
Fx lb( kN) |
Fy lb( kN) |
Fz lb( kN) |
665( 2.96) |
1,045( 4.66) |
3,970( 17.68) |
1 Tabulated values are for non-elevator applications only. | ||
2 Minimum safety factor, Ω, for tabulated values is 2.1. | ||
3 Multiply tabulated values by 1.5 to obtain LRFD values. | ||
4 Load values are for base connector only. Design professional is responsible | ||
for checking concrete and fastener strength. | ||
5 See Figure 101. | ||
Fx lb( kN) |
Fy lb( kN) |
Fz lb( kN) |
995( 4.43) |
1,570( 7.00) |
5,305( 23.62) |
1 Tabulated values are for non-elevator applications only. | ||
2 Maximum resistance factor, φ, for tabulated values is 0.7. | ||
3 Load values are for base connector only. Design professional is | ||
responsible for checking concrete and fastener strength. | ||
4 See Figure 101. | ||