Description |
Standard |
Grade |
F y, ksi
( MPa)
|
F u, ksi
( MPa)
|
MT-C-GS HA OC |
( GB / T 1591) |
( Q355 B) |
51.49
( 355)
|
68.17
( 470)
|
|
MT-C-GS HA US OC ASTM A1011 1
HSLAS-F
Grade 50 MOD 1
|
51.49
( 355)
|
68.17
( 470)
|
||
1 ASTM A1011 HSLAS Grade 50 MOD is an enhanced version of ASTM A1011 HSLAS Grade | ||||
50 with Fu >= 470MPa and Fy >= 355MPa. | ||||
A. |
MT-90H |
B. |
MT-70, MT-80( short side) |
lb( kN) |
lb( kN) |
lb( kN) |
790 |
225 |
645 |
( 3.53) |
( 1.02) |
( 2.87) |
1 Minimum safety factor Ω, for tabulated values is 2.32. | ||
2 Multiply tabulated values by 1.5 to obtain minimum Load | ||
and Resistance Factor Design( LRFD) values. | ||
3 See Figure 58. | ||
Table 219- Limit State Design( LSD) Load Data 1, 2 | ||
Fx lb( kN) |
Fy lb( kN) |
Fz lb( kN) |
1,120( 5.00) |
325( 1.45) |
910( 4.06) |
1 Maximum resistance factor φ, for tabulated values is 0.74. | ||
2 See Figure 58. | ||
Fx lb( kN) |
Fy lb( kN) |
Fz lb( kN) |
My lb ft( kN m) |
2,830( 12.6) |
470( 2.1) |
1,145( 5.09) |
630( 0.857) |
1 Minimum safety factor Ω, for tabulated values is 2.0. | |||
2 Multiply tabulated values by 1.5 to obtain minimum LRFD values. | |||
3 See Figure 59. | |||
lb( kN) |
lb( kN) |
lb( kN) |
lb( kN m) |
4,890 |
670 |
1,660 |
890 |
( 21.7) |
( 3.0) |
( 7.4) |
( 1.21) |
1 Maximum resistance factor φ, for tabulated values is 0.75. | |||
2 See Figure 59. | |||
A. |
MT-90H |
B. |
MT-70, MT-80( short side) |