MT EDB Connectors Technical Supplement Guide
1.0 MODULAR SUPPORT SYSTEM MT-BRL-EDB
Description
Guide rail bracket connection to MT-90 and MT-100 .
Material Specifications
Standard 1 Grade 1 F y , ksi ( MPa ) F u
, ksi ( MPa ) GB / T 1591 Q355 B 51.49 ( 355 ) 68.17 ( 470 )
1 . Mechanical properties of GB / T 1591 Grade Q355 B meet or exceed the mechanical properties of ASTM A1011 SS Grade 50 .
Corrosion Protection
Electro-Galvanized ( EG )
MT-BRL-EDB M12 MT-BRL-EDB M16
����� “) �
������
���� “ ���������� “)
MT-BRL-EDB M12
���
������ “)
����
�� “)
���
�� “)
��� �������� “)
�� ���� “)
MT-BRL-EDB M16
���� “ �������� “)
������
mm ( in )
Ordering Information
Description
Weight Per Piece lbs ( kg )
Quantity Piece ( s )
Item No .
MT-BRL-EDB M12 4.39 ( 1.99 ) 10 2353806
MT-BRL-EDB M16 4.48 ( 2.03 ) 10 2353807
|
������
������ “ ������ “)
����� “) �
���
������ “)
|
����
�� “)
|
���
�� “)
��� �������� “)
��
���� “)
������ “ �������� “)
������
mm ( in )
|
Figure 17 - L-Bracket Connection to MT Girder
Table 39 - Allowable Strength Design ( ASD ) Load Data 1 , 2 , 3 , 4 , 5 , 6
F x lb ( kN )
F y lb ( kN )
F z lb ( kN )
M x lb ft ( kN m )
M z lb ft ( kN m )
3,380 |
2,630 |
600 |
1,980 |
560 |
( 15.05 ) |
( 11.70 ) |
( 2.67 ) |
( 2.69 ) |
( 0.76 ) |
1 . Tabulated values are for elevator divider beam applications only . 2 . Tabulated values must be used in conjunction with the stiffness values shown in Table 41 . 3 . Tabulated values are for elevator divider beam applications only . 4 . Minimum safety factor , Ω , for tabulated values is 2.75 . 5 . Multiply tabulated values by 1.5 to obtain minimum Load and Resistance Factor Design
( LRFD ) values . 6 . See Figure 17 .
Table 40 - Limit State Design ( LSD ) Load Data 1 , 2 , 3 , 4 , 5
A . MT-90 / 100 ( long side ) B . L-bracket not by Hilti
F x lb ( kN )
F y lb ( kN )
F z lb ( kN )
M x lb ft ( kN m )
M z lb ft ( kN m )
5,410 |
4,205 |
900 |
2,580 |
720 |
( 24.08 ) |
( 18.72 ) |
( 4.01 ) |
( 3.50 ) |
( 0.98 ) |
1 . Tabulated values are for elevator divider beam applications only . 2 . Tabulated values must be used in conjunction with the stiffness values shown in Table 41 . 3 . Tabulated values are for elevator divider beam applications only . 4 . Maximum resistance factor , Φ , for tabulated values is 0.5 . 5 . See Figure 17 .
Table 41 - EDB L-Bracket Connection Stiffness Data 1 , 2
Connector MT-BRL-EDB M12
MT-BRL-EDB M16 k Fx kips / in ( kN / mm ) k Fy kips / in ( kN / mm ) k Mz lb ft / rad ( kN m / rad )
2,855 |
68.75 |
12,905 |
( 500 ) |
( 12.04 ) |
( 17.50 ) |
2,855 |
68.75 |
12,905 |
( 500 ) |
( 12.04 ) |
( 17.50 ) |
1 . Spring stiffness values are to be used in elevator divider beam applications . 2 . The rotational spring stiffness , k My
, for MT-BRL-EDB L-bracket connections should be set to zero .
2023
12