Modular Support Systems Technical Supplement - USEN July 2023 | Page 11

MT EDB Connectors Technical Supplement Guide
1.0 MODULAR SUPPORT SYSTEM MT-BRS-EDB
Description
Guide rail bracket connection to MT-80 .
Material Specifications
Standard 1 Grade 1 F y , ksi ( MPa ) F u
, ksi ( MPa ) GB / T 1591 Q355 B 51.49 ( 355 ) 68.17 ( 470 )
1 . Mechanical properties of GB / T 1591 Grade Q355 B meet or exceed the mechanical properties of ASTM A1011 SS Grade 50 .
Corrosion Protection
Electro-Galvanized ( EG )
MT-BRS-EDB M12 MT-BRS-EDB M16
����� “) �
������
���� “ ��������� “)
���
������ “)
MT-BRS-EDB M12
�� �� “)
����� “)
���
������ “)
MT-BRS-EDB M16
���� “ �������� “)
������
mm ( in )
Ordering Information
Description
Weight Per Piece lbs ( kg )
Quantity Piece ( s )
Item No .
MT-BRS-EDB M12 3.66 ( 1.66 ) 6 2353808 MT-BRS-EDB M16 3.76 ( 1.71 ) 6 2353809
����� “) �
������
������ “ ��������� “)
���
������ “)
�� �� “)
���
������ “)
������ “ ���������� “)
������
����� “) mm ( in )
Figure 15 - L-Bracket Connection to MT Girder
Table 33 - Allowable Strength Design ( ASD ) Load Data 1 , 2 , 3 , 4 , 5 , 6
F x lb ( kN )
F y lb ( kN )
F z lb ( kN )
M x lb ft ( kN m )
M z lb ft ( kN m )
3,145
2,220
600
855
550
( 14.00 )
( 9.89 )
( 2.67 )
( 1.16 )
( 0.75 )
1 . Tabulated values are for elevator divider beam applications only . 2 . Tabulated values must be used in conjunction with the stiffness values shown in Table 35 . 3 . Tabulated values are for elevator divider beam applications only . 4 . Minimum safety factor , Ω , for tabulated values is 2.3 . 5 . Multiply tabulated values by 1.5 to obtain minimum Load and Resistance Factor Design
( LRFD ) values . 6 . See Figure 15 .
Table 34 - Limit State Design ( LSD ) Load Data 1 , 2 , 3 , 4 , 5
A . MT-80 ( long side ) B . L-bracket not by Hilti
F x lb ( kN )
F y lb ( kN )
F z lb ( kN )
M x lb ft ( kN m )
M z lb ft ( kN m )
5,035
3,555
900
1,105
715
( 22.40 )
( 15.82 )
( 4.01 )
( 1.50 )
( 0.97 )
1 . Tabulated values are for elevator divider beam applications only . 2 . Tabulated values must be used in conjunction with the stiffness values shown in Table 35 . 3 . Tabulated values are for elevator divider beam applications only . 4 . Maximum resistance factor , Φ , for tabulated values is 0.6 . 5 . See Figure 15 .
Table 35 - EDB L-Bracket Connection Stiffness Data 1 , 2
Connector MT-BRS-EDB M12
MT-BRS-EDB M16 k Fx ( kips / in ) ( kN / mm ) k Fy ( kips / in ) ( kN / mm ) k Mz lb ft / rad ( kN m / rad )
2,855
57.84
11,785
( 500 )
( 10.13 )
( 15.98 )
2,855
57.84
11,785
( 500 )
( 10.13 )
( 15.98 )
1 . Spring stiffness values are to be used in elevator divider beam applications . 2 . The rotational spring stiffness , k My
, for MT-BRS-EDB L-bracket connections should be set to zero .
2023
10