MBTEAM Katalozi | Page 92

BOLLY® XL - HEAT EXCHANGERS TECHNICAL DATA Data have been calculated on following basis: 1) Primary circuit at T1 and proper energy source; 2) Production of DHW in continue way from 10 °C at t2; 3) DHW that can be taken in the first 10’ and in the first hour from storage at 60°C, input 10°C and output 45°C; 4) Sanitary water according to UNI CTI 8065. FIXED HEAT EXCHANGER t2 T1 Storage Volume Model [liters] 200 T2 t1 189 300 291 500 497 Maximum power exchange (kw) with primary Ignition time (minutes) from 10 °C to t2 DHW continuous production lt/h within at t1, secondary within 10-45 °C and constant and primary at t1 10-45 °C and primary at t1 use of DHW production T1/t2 55/50 40 48 39 48 44 57 65/60 42 50 40 51 46 60 T1 70/60 30 36 29 36 33 43 80/60 20 24 19 24 22 29 55 21,2 19,1 34,9 30,8 54,5 47,9 65 31,2 27,6 50,9 43,7 78,6 66,7 T1 70 36,3 31,7 58,9 50 90,6 75,9 80 46,6 40,2 75,1 62,7 114,6 94,1 55 522 472 862 762 1349 1185 65 773 681 1260 1081 1946 1651 70 899 785 1459 1238 2243 1877 90 80 1153 995 1860 1552 2838 2330 100 PRESSURE LOSS - FIXED HEAT EXCHANGER BOLLY® XL Flow Rate [lt/min] 0 10 20 30 40 50 60 70 80 2500 200 2000 300 150 1500 200 100 [mm H 2O] 3000 250 [mbar] 300 1000 50 500 0 0 0 1 2 3 4 5 6 Flow Rate [m 3 /h] Flow Rate [lt/min] 0 10 20 30 40 50 60 70 80 90 100 300 3000 500 2000 150 1500 100 1000 50 500 0 0 0 1 2 3 Flow Rate [m 3 /h] 90 4 5 6 [mm H 2O] 2500 200 [mbar] 250