MBTEAM Katalozi | Page 30

EXTRA2 - HEAT EXCHANGERS TECHNICAL DATA Cordivari Heat Exchangers, with tubes bent to the bottom, is able to heat the complete quantity of volume in an homogenous way. Energy storaging is therefore improved and Ignition time data have to be referred to the complete volume of the tank, while in a traditional straight heat exchangers equipped calorifires, a range between 9-17% of Volume remain cold. UPPER STRAIGHT HEAT EXCHANGERS t2 Model Storage Volume [liters] 200 500 282 484 1000 600 822 2000 1147 2500 1144 3000 1656 4000 2128 5000 t1 148 1500 T2 300 800 T1 96 2814 Maximum power exchange (kw) with primary Ignition time (minutes) from 10 °C to t2 DHW continuous production lt/h within at t1, secondary within 10-45 °C and constant and primary at t1 10-45 °C and primary at t1 use of DHW production 55/50 57 74 57 73 52 66 62 75 80 100 68 82 70 84 59 71 71 88 71 89 78 99 T1/t2 65/60 70/60 57 39 75 52 57 39 73 52 52 36 55 46 62 42 76 53 80 55 100 70 68 47 83 57 70 48 85 59 59 40 72 50 72 49 89 62 72 50 90 63 78 54 100 71 T1 80/60 25 33 25 33 23 30 27 34 35 45 30 37 30 37 25 32 31 40 32 41 35 46 55 7 6 11 9 23 19 33 28 32 26 51 44 69 59 84 71 100 84 131 110 162 135 65 11 9 18 14 37 29 53 44 51 41 82 68 111 93 134 111 159 130 207 168 253 204 T1 70 14 11 21 16 44 35 64 52 61 48 98 81 133 111 160 131 190 154 247 198 301 239 80 18 14 28 22 59 46 86 69 82 65 133 109 180 148 216 174 255 204 330 260 400 312 55 179 142 275 220 573 468 817 690 783 647 1259 1077 1702 1468 2069 1758 2465 2086 3242 2723 3998 3338 65 283 219 436 340 911 724 1312 1079 1252 1008 2026 1690 2741 2306 3313 2738 3931 3229 5126 4167 6275 5055 70 339 259 521 403 1090 857 1573 1284 1501 1198 2430 2011 3293 2744 3969 3249 4698 3821 6112 490 9 7459 5930 80 456 344 702 535 1468 1139 2129 1715 2029 1599 3295 2687 4463 3668 5358 4318 6325 5057 8179 6448 9924 7735 LOWER CURVED HEAT EXCHANGERS t2 Model Storage Volume [liters] 200 190 300 285 T1 500 485 T2 800 790 t1 1000 995 1500 1440 2000 1980 2500 2313 3000 2921 4000 3765 5000 4985 Maximum power exchange (kw) with primary Ignition time (minutes) from 10 °C to t2 DHW continuous production lt/h within at t1, secondary within 10-45 °C and constant and primary at t1 10-45 °C and primary at t1 use of DHW production 55/50 113 147 112 145 90 114 101 124 82 101 120 145 121 146 118 145 128 456 126 159 137 176 T1/t2 65/60 70/60 113 148 113 146 90 115 101 125 83 100 119 146 122 147 119 146 127 157 127 161 138 179 T1 T1 28 55 65 70 80 55 65 70 80 49 65 48 65 39 51 44 55 36 44 51 64 52 65 51 65 55 70 56 73 61 82 77 102 76 102 62 80 69 86 56 69 82 100 83 101 81 101 87 110 87 112 96 125 80/60 7,3 6 11 9 23 19 33 28 51 44 51 44 69 59 69 59 100 84 131 110 162 135 12 9 17 14 37 29 53 44 82 68 81 68 111 93 111 93 159 130 207 168 253 204 14 11 21 16 44 35 64 52 98 81 98 81 133 111 133 111 190 154 247 198 301 239 18 13,9 28 21,6 59 46 86 69 133 108 133 108 180 148 180 148 255 204 330 260 401 312 178 141 274 219 571 466 815 688 1257 1076 1256 1075 1699 1465 1699 1465 2461 2082 3236 2718 3992 3332 283 218 435 339 909 722 1310 1077 2024 1689 2022 1687 2738 2302 2738 2302 3926 3224 5121 4151 6270 5049 338 258 520 402 1088 856 1572 1282 2429 2010 2428 2008 3288 2741 3288 2741 4694 3817 6105 4903 7450 5923 455 344 701 534 1467 1137 2128 1712 3293 2685 3290 2684 4453 3665 4453 3665 6321 5053 8168 6443 9921 7727