March May Pumps 1 | Page 47

MC RANGE Magnetically Driven Multi-stage Centrifugal FEATURES MC pumps are designed to pump mild liquids such as water and glycol in high head medium flow applications. n n n n n n n Efficient and quiet Available with brushed and brushless DC motors n No seals Thermally broken Max. PP temperature 85°C Max. Ryton temperature 100°C Max. PP system operating pressure 3 bar Max. Ryton system operating pressure 6 bar MC-2P 50/60Hz IP44 Non-Corrosive Liquids CAUTION! VERY HOT WATER +100 °C MATERIALS OF CONSTRUCTION Component Pump Housing Impeller Impeller Magnet Spindle O-Ring MC-P Polypropylene Polypropylene Stront Ferrite 316 SS Nitrile MC-R Ryton Ryton Stront Ferrite 316 SS Nitrile Options Polypropylene Ceramic Viton, FEP, EPDM MC-2 50/60Hz IP44 MC-2 50/60Hz IP55 PERFORMANCE 2900 rpm, SG 1.0 40 DIMENSIONS Not to scale. Specifications are subject to change. Inlet: Outlet: 1" BSP.F ½" BSP.M 21mm hose tail 35 C 81.5 D B 30 40.3 MC-6 25 MC-5 A Head metres 20 MC-4 15 MC-3 Model A mm B mm C mm D mm Freq Hz Power kW 10 MC-2 MC-2 MC-3 5 MC-3 MC-2 MC-4 MC-5 MC-6 0 0 5 10 15 20 25 30 35 40 45 50 55 60 65 160.0 186.0 186.0 186.0 184.0 184.0 184.0 107.0 131.0 131.0 131.0 133.0 133.0 133.0 65.90 65.90 90.10 90.10 114.30 138.50 162.70 169.0 212.0 212.0 212.0 210.0 210.0 210.0 50 60 50 60 50 50 50 0.25 0.37 0.37 0.55 0.55 0.55 0.55 litres/min Individual model data sheets are available for further information. 19/09/2012 March May Ltd, Howard Road, Eaton Socon, St Neots, PE19 8NZ, UK Tel: +44 (0) 1480 214444 Fax: +44 (0) 1480 405336 E-Mail: [email protected] Website: www.marchmay.co.uk